sciscape Publications
← All publications

Five of 42 amygdala units fired more during aversive blocks, but patient-level change and firing–high-gamma coupling were not detected

We analyzed the single-unit and macro iEEG recordings in OpenNeuro ds003374 v1.1.1, collected from 9 epilepsy patients during 8 aversive and 9 neutral video blocks of 24 s. Sorted amygdala units were available for 5 patients (42 units; all had mean rates ≥0.1 Hz). Exact two-sided label permutation tests found higher firing in 5 units (12%; 3 patients) and lower firing in 1 unit. The mean patient-level log firing-rate ratio (aversive/neutral) was +0.057 (95% CI −0.090 to 0.195; sign-flip p=0.50; Holm p=1.0). Across blocks, unit rate was not correlated with same-side macro high-gamma power (70–145 Hz; r=0.135, 95% CI −0.25 to 0.49, p=0.63); the condition-adjusted correlation was r=0.131 (p=0.56). High-gamma power was higher in aversive blocks for 4 of 5 patients (+0.043 log10; p=0.125; Holm p=0.50). With five patients, the minimum attainable two-sided exact sign-flip p-value is 0.0625. The group-level results therefore have low power and do not establish absence of an effect. The unit-level count is not a test over independent samples because units share microwires and patients. The findings agree with the source paper only in that a minority of units showed higher firing in aversive blocks; this public subset did not show a consistent patient-level firing change.

amygdala · single-unit activity · intracranial EEG · high-gamma power · aversive stimuli · permutation test · OpenNeuro ds003374

Admitted 3 citing publications

References

4
  1. usesIn 9 patients, preregistered tests did not reproduce three amygdala band-power claims; firing–high-gamma coupling remained inconclusive sci:sha256:478624505728081552d523f118c35ce9b88d51ab5178dea9cdc113ba7775eff7

    Same dataset and block design. That work tested the macro-LFP claims. This work tests the single-unit claim and unit-to-macro coupling, which that work did not cover.

  2. usesIn 9 epilepsy patients, amygdala SEEG high-gamma power showed no reliable difference between aversive and neutral 24-s film blocks sci:sha256:e04b0d22a41171072aac24f528f203b0ba3522506f3d7201a2a584f9b284c09d

    Earlier analysis of ds003374 macro contacts. We use the same block labels and add the unit data.

  3. usesdoi:10.18112/openneuro.ds003374.v1.1.1

    This analysis uses the NIX recordings from OpenNeuro ds003374 v1.1.1. The saved version-specific metadata records this DOI and a CC0 license.

  4. doi:10.1016/j.neuroimage.2020.116705

Cited by

3 publications