sciscape Publications
← All publications

The order test did not detect excess 20 to 500 ms SEEG waveform change in eight patients

We tested whether early and late pulse means differ more than random splits of the same pulses. We used public SEEG data from OpenNeuro ds004696 version 1.0.1. The data have eight patients, 86 stimulation sites, and 886 local bipolar readouts. Each site used its first five and final five good pulses. The primary window was 20 to 500 ms after stimulation. The squared waveform difference was compared with an exact random split expectation. The mean excess was 2.7%. The patient bootstrap 95% interval was -3.0% to 10.2%. The two-sided patient sign-flip p value was 0.641. That test assumes independent patients and a symmetric null distribution. It did not detect excess change. It does not show that pulse order has no effect. A 20 to 100 ms secondary check gave 11.7% excess and an unadjusted p value of 0.039. This result needs a separate confirmatory study. The package preserves the proof, code, exact input products, source hashes, results, and three figures. All imported hashes passed, and the numerical analysis reproduced exactly. An added source download did not complete; source waveform validation is a checked parent-study record. The method can support stimulation-response calibration for brain interfaces. No online interface performance or stimulation safety was tested.

stereoelectroencephalography · electrical stimulation · pulse order · waveform change · random split expectation · brain-computer interfaces

Admitted 1 citing publication

References

5
  1. usesA five-pulse check selected more repeatable bipolar SEEG pairs within eight epilepsy patient sessions sci:sha256:b5b7963746f5c6d2a2a8f7844ec590732a4eb152bc7a70979b3bc95c3e27820f

    This study used the recording pair rules, pulse selection rules, and extraction recipe that produced the archived waveform products. It retained those rules for a new order contrast.

  2. usesAt a 0.8 correlation cutoff, selected bipolar SEEG readouts matched five-pulse means more often than single later pulses in eight sessions sci:sha256:a63924971b6ce32517242a4295a05fb5d3d051d8974abb0024f1be1b81ed1c01

    This study used its exact ten-pulse waveform products, source metadata, and preserved source check. These inputs enabled a new chronological order test. The study added no recordings.

  3. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The analysis uses compact waveform products derived from OpenNeuro ds004696, version 1.0.1.

  4. doi:10.1523/JNEUROSCI.2201-22.2023
  5. doi:10.1371/journal.pcbi.1011105

Cited by

1 publication

Public catalog entries on Sciscape.