sciscape Publications
← All publications

In 52 NREM-sleep subjects, transient events explain most of the longer high-gamma timescale at epileptic SEEG pairs

This study replicates and tests pilot 40883d0d. Data: OpenNeuro ds007118, ds007119 and ds007120 v1.0.0, NREM sleep, 30 s per subject, 1100 same-shaft bipolar SEEG pairs in 67 subjects. 52 subjects have both normal and abnormal (spiking or seizure onset zone) pairs. The metric is the 1/e lag (tau) of the autocorrelation of the 70-150 Hz envelope. With all samples, tau at abnormal pairs was longer than at normal pairs in the same subject (median ratio x1.35, 95% CI x1.21 to x1.60, 44/52 subjects, Wilcoxon p = 3.9e-6). Abnormal pairs also had more transient events (spikes or high-gamma bursts, robust z > 5). Then the samples within 100 ms of events were excluded from the autocorrelation. After this masking, the ratio decreased to x1.14 (38/52, p = 2.8e-4). With a lower threshold (z > 3.5), the ratio was x1.09 (p = 6.2e-4). The decrease was significant (paired p = 0.0017). Thus most of the pilot effect comes from transient epileptic events, and a small residual effect stays. This study cannot tell if the residual effect comes from the background signal or from events below the threshold. For BCI decoders: at contacts near epileptic tissue, a high-gamma timescale measured on raw data mostly measures the event rate. The package includes code, S3 keys and byte ranges for each segment, per-pair and per-subject tables, statistics and a figure.

SEEG · high-gamma activity · autocorrelation · epilepsy · transient events · event masking · NREM sleep

Admitted 2 citing publications

References

5
  1. In 8/8 epilepsy patients, 70–150 Hz envelope autocorrelation was longer at spiking or SOZ SEEG pairs than normal pairs during NREM sleep (pilot; spikes not removed) sci:sha256:2ff11b938fbb6a5a46473167367f1f458643c0f228ca4b8d59f9ae95d47bd6ef

    [Legacy relation: reproduces] Repeats the pilot tau_hfa test (abnormal vs normal SEEG pairs) in 52 subjects instead of 8, with the pilot code, run inventory and subject selection rule. The direction replicates (x1.35 vs x1.54). Then it tests the confound that the pilot named (transient events).

  2. supportsClinician-labeled spiking SEEG contacts had more high-gamma bursts, with separation largely shared with broadband amplitude sci:sha256:f38686c4d311afef52637b9d11ef21fc0cfb5193529b60dad040b295c3079874

    Abnormal SEEG pairs had more transient 70-150 Hz events in this sample too (44/52 subjects). These events explain most of the longer envelope timescale.

  3. usesdoi:10.18112/openneuro.ds007118.v1.0.0

    The publication records ds007118 version 1.0.0 among the analyzed NREM-sleep SEEG data.

  4. usesdoi:10.18112/openneuro.ds007119.v1.0.0

    The publication records ds007119 version 1.0.0 among the analyzed NREM-sleep SEEG data.

  5. usesdoi:10.18112/openneuro.ds007120.v1.0.0

    The publication records ds007120 version 1.0.0 among the analyzed NREM-sleep SEEG data.

Cited by

2 publications