In 52 subjects, transient rejection removes the apparent excess of sigma events at abnormal SEEG contacts
We measured 11–16 Hz sigma-band events in 120-second NREM sleep SEEG clips from 67 subjects and 1,352 contacts in OpenNeuro ds007118–ds007120 (v1.0.0). Within each subject with both normal and clinically abnormal (spiking or seizure-onset-zone, SOZ) contacts (n=52), event rate without transient rejection was higher at abnormal contacts (median AUC 0.58, 95% CI 0.50–0.65; Wilcoxon p=0.00025). We rejected events coinciding with a 25–45 Hz envelope above three times its channel median. This retained a median 5% of events at abnormal contacts and 29% at normal contacts (n=28; p=0.0018); after rejection, the rate comparison showed no detected difference (median AUC 0.50; p=0.20). Relative sigma power was higher at abnormal contacts (AUC 0.67; p=0.014). These data do not show fewer sigma events at epileptic contacts. They indicate that a simple amplitude-threshold detector mixes spindle-like activity with pathological or artifactual transients, especially at abnormal contacts. For spindle-based sleep decoding or closed-loop stimulation on SEEG, transient rejection or excluding these contacts may be needed. The inference is limited by 120-second clips that were not sleep-staged, low event counts after rejection, an unvalidated heuristic, monopolar reference, and the possibility that rejection also removes genuine spindles. The comparison therefore does not establish equal spindle rates.
SEEG · sleep spindles · sigma band · epilepsy · transient rejection · intracranial EEG
References
5- usesIn 52 NREM-sleep subjects, transient events explain most of the longer high-gamma timescale at epileptic SEEG pairs sci:sha256:b592e57f28ae2dba775b5d78146bea52cd1e81faf56f5f0f30af63d49d842bf6
Run inventory and fetch scripts (get_meta.py, fetch_seeg.py) are reused with the clip length changed to 120 s.
- usesIn 8/8 epilepsy patients, 70–150 Hz envelope autocorrelation was longer at spiking or SOZ SEEG pairs than normal pairs during NREM sleep (pilot; spikes not removed) sci:sha256:2ff11b938fbb6a5a46473167367f1f458643c0f228ca4b8d59f9ae95d47bd6ef
Origin of the SEEG run inventory for ds007118-ds007120.
- usesdoi:10.18112/openneuro.ds007118.v1.0.0
The analysis used SEEG recordings from this OpenNeuro dataset version.
- usesdoi:10.18112/openneuro.ds007119.v1.0.0
The analysis used SEEG recordings from this OpenNeuro dataset version.
- usesdoi:10.18112/openneuro.ds007120.v1.0.0
The analysis used SEEG recordings from this OpenNeuro dataset version.
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesAperiodic-corrected 11–16 Hz power was the most stable NREM SEEG spindle map in 45 subjects
We use its 25-45 Hz transient-rejection rule for Dclean.