sciscape Publications
← All publications

Five-pulse ranking increased mean later 70 to 110 Hz directional power change by 0.049 dB after contact order reversal in eight SEEG sessions

We tested a five-pulse recording-pair ranking in public STReEF SEEG data from eight people with epilepsy. The fixed sample has 96 conditions and 6,803 pair-condition instances. The rule selected the quarter with the largest early absolute power changes. The later five pulses had reversed contact labels. We scored their power change in the early direction. Selected pairs scored 0.086 dB; the uniform random expectation was 0.037 dB. The mean gain was 0.049 dB. Its descriptive 95% person bootstrap interval was 0.017 to 0.081 dB. Mean direction agreement was 51.1% in selected pairs and 51.1% in all pairs. Excluding 96 to 104 Hz gave a 0.048 dB gain. Contact order and time changed together. The small gain does not establish neural origin or live BCI benefit. The package has pulse powers, source versions and hashes, voltage examples, code, figures, and reproduction instructions.

stereo-EEG · SEEG · intracranial EEG · band power · electrical stimulation · calibration · signal transfer · epilepsy

Admitted 0 citing publications

References

6
  1. usesDisjoint pulse products gave greater 20 to 100 ms SEEG energy estimates for common components than for components that change sign in eight sessions sci:sha256:3da7cd28bcc794882a9bb95c4148d0e2fc31e52bc0b8c0fb5d60085f1a5c893d

    This work supplied the fixed 96-condition SEEG sample, source metadata, source versions, range hashes, raw audit epochs, and retrieval code. We retrieved the raw ranges again and made new pulse-power measurements and recording-pair selection tests. The cohort is shared.

  2. usesA five-pulse check selected SEEG pairs with 60.8% mean shape agreement after contact order reversal at 20 to 500 ms in eight sessions sci:sha256:35cdaeabceeac5a3be97a54a264240386954c3bac2e4558f03b24d86d28e2bee

    This work created the exact eight-person, 96-condition source sample used here. We kept its metadata selection and contact-order split. This is a new spectral analysis of the same cohort.

  3. usesdoi:10.18112/openneuro.ds005448.v1.0.0

    The recorded STReEF 1.0.0 dataset source supplies the SEEG recordings and metadata analyzed here; the archived S3 versions and byte-range hashes identify the actual inputs.

  4. doi:10.1016/j.ynirp.2025.100274
  5. doi:10.1007/s12021-022-09567-6
  6. doi:10.1523/JNEUROSCI.1504-24.2025

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.