SEEG variance after mean removal at 20 to 100 ms exceeded a baseline of equal length in eight epilepsy sessions
We tested residual voltage variance at 20 to 100 ms after pulses in public OpenNeuro ds004696 version 1.0.1. We used eight epilepsy SEEG sessions, 86 stimulation sites, and 886 site/readout pairs. The calculation removed each pulse temporal mean and a separate mean waveform for each five-pulse group. With an equal-length baseline, the geometric variance ratio was 1.609, with a descriptive 95% interval of 1.355 to 1.935. With a longer baseline, the ratio was 0.512. Each patient mean changed from below one to above one. Fixed subsets supported the average direction. A stationary-noise proof showed how temporal mean removal can create a duration effect. The archive preserves voltage products, selected voltage epochs, source metadata, results, figures, tables, and reproduction records. GPL analysis and extraction scripts are excluded from the SCI payload. The result concerns processed clinical voltage. It does not establish a neural cause or online interface performance.
SEEG · residual variance · electrical stimulation · baseline · signal measurement · epilepsy
References
5- SEEG variance after mean removal was higher 20 to 500 ms after pulses than before pulses in eight epilepsy sessions sci:sha256:8ee73a7bddac5f833636033f8f8b842e4487d5f60accef4748f5c9c259e4c1d8
[Legacy relation: reproduces] We reproduce its full-window geometric residual variance ratio of 1.640502. We resolve its stated unequal-length early-window limit with a baseline of equal length.
- usesMean signed shared power fraction increased 17.63 percentage points more at 20–100 than at 100–500 ms after matched baseline subtraction in eight epilepsy SEEG sessions sci:sha256:ea937a7772df7e9e7ba2b56087e0b2c7fe8a3f1d3005ffe0232dfc4a1d31cfa3
This publication supplies the exact six-window pulse matrices and source extraction code. We use them to test residual variance with equal sample counts, a different endpoint from shared power fraction.
- usesReplacing data after pulses with zero changed theta phase labels 50 ms before pulses with a centered 1 s filter in eight SEEG sessions sci:sha256:17598dc78a0c15e696342a9b71328e9454995f0971df9ffd9f6f463a017449de
This publication supplies full precision voltage for one fixed readout per site. We use those 86 readouts to check the matrix variance calculation and test baseline position.
- usesdoi:10.18112/openneuro.ds004696.v1.0.1
The analysis uses public OpenNeuro ds004696 version 1.0.1; the importer record identifies this exact version and its CC0 license.
- doi:10.1523/JNEUROSCI.2201-22.2023
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.