sciscape Publications
← All publications

SEEG variance after mean removal was higher 20 to 500 ms after pulses than before pulses in eight epilepsy sessions

We tested whether voltage variation before a pulse described SEEG variation after the pulse. SEEG means stereoelectroencephalography. We used OpenNeuro ds004696 version 1.0.1, with eight epilepsy sessions, 86 stimulation sites, and 886 remote bipolar recording instances. We selected the first five and final five good pulses at each site. We removed a separate mean waveform from each five-pulse group. We compared 20 to 500 ms after a pulse with -980 to -500 ms before it. Both windows had 983 samples. We averaged log variance ratios over readouts, sites, and patients, with equal weights at each level. The geometric ratio was 1.641. The descriptive 95 percent patient bootstrap interval was 1.373 to 2.126. All eight patient means were above one. Separate pulse groups and alternative weights retained the increase. This result shows a variance mismatch for these windows and selected recordings. It does not isolate neural noise or test an online brain-computer interface. The package contains exact input products, code, tables, three figures, source hashes, and instructions to repeat the test. We rebuilt all eight public source files and checked the variance directly from full trial waveforms.

stereoelectroencephalography · electrical stimulation · residual variance · brain-computer interface · epilepsy

Admitted 4 citing publications

References

4
  1. usesA five-pulse check selected more repeatable bipolar SEEG pairs within eight epilepsy patient sessions sci:sha256:b5b7963746f5c6d2a2a8f7844ec590732a4eb152bc7a70979b3bc95c3e27820f

    Uses its exact trial waveform products, readout inclusion rules, source metadata, and public extraction code. These inputs permit a comparison of residual variance after pulses with variance before pulses. The present study rebuilds the source products and adds direct variance checks, new outcome calculations, tables, and figures.

  2. usesMean scaled SEEG waveform error at 20–500 ms was 0.032 below a five-pulse estimate in eight patient sessions sci:sha256:6546d7b768dee897061cfc0f38d7ba2a1bf9b4733bb01186ca978a0b5855224e

    Uses its question about a five-pulse variance estimate for later waveform error to motivate a comparison with variance before pulses. Both studies use the same public cohort. The present study does not replicate its prediction test or use its code or data products.

  3. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    Uses the processed trial data from OpenNeuro ds004696 version 1.0.1, the exact recorded source release.

  4. usesdoi:10.1523/JNEUROSCI.2201-22.2023

    Cites the source study describing the electrical stimulation experiment represented in the analyzed dataset.

Cited by

4 publications

Public catalog entries on Sciscape.