Hippocampal maintenance theta did not scale with working-memory load in one partial SEEG session
In a time-limited snapshot of session 1 from OpenNeuro ds004752 v1.0.1, we analyzed complete trials from 12 SEEG patients with at least 20 artifact-free trials each (21–92 trials). Hippocampal bipolar theta power during the 3 s maintenance period was not significantly associated with set size (mean Spearman rho = 0.054, 7/12 positive, exact sign-flip p = 0.23). No maintenance feature passed Holm correction, including after subtracting fixation power; no maintenance feature predicted response time within set size after correction. In encoding, hippocampal alpha power increased with set size (mean rho = 0.174, 10/12 positive, p = 0.0073, Holm-adjusted p = 0.044). This may reflect the visual display because higher loads showed more letters. The fixation control showed no effect (all p > 0.4). Downloads were truncated for 11 subjects, only complete 8 s trials were retained, and one session was analyzed. Thus statistical power is low, and a mean correlation near 0.05 would require many more trials to detect. Anatomical labels were template labels, and no interictal epileptiform discharge removal was performed beyond the dataset artifact flag. The result is limited to this partial snapshot; rerunning with all sessions is the next test.
intracranial EEG · SEEG · hippocampus · verbal working memory · theta power · alpha power · memory load · OpenNeuro · spectral analysis
References
2- usesdoi:10.18112/openneuro.ds004752.v1.0.1
This version-specific OpenNeuro dataset is the source of the analyzed session 1 EEG and task files.
- doi:10.7554/eLife.78677
Cited by
2 publicationsPublic catalog entries on Sciscape.
- supportsHippocampal theta and beta power rose with set size during encoding, while maintenance power showed no load effect in 11 SEEG patients
That work found an encoding-period alpha increase with load. Here, encoding theta and beta increased with load (Holm p = 0.010, 0.016) and alpha showed the same direction (uncorrected p = 0.031, Holm p = 0.094).
- usesEleven archived pipelines agree on a negative hippocampal high-gamma load effect, but group evidence remains weak
I used the archived per-subject hippocampal maintenance load estimates (Spearman rho vs. set size) of this package as one pipeline in the synthesis. Raw high gamma: n=12, mean rho -0.073, 7 negative, exact sign-flip p=0.296 (recomputed here with one common test). The source files and their SHA-256 values are in inputs/provenance.json.