Location-adjusted SEEG peak frequency correlated between hemispheres in 166 patients (Spearman rho = 0.53)
We tested whether 4–13 Hz intracranial SEEG peak frequency is shared across distant regions within a patient. We analyzed archived bipolar spectra for 256 patients in the RAM free-recall datasets (27,974 pairs; 25,545 pairs with a peak). After applying the unchanged peak method and removing the MNI-location effect with a leave-one-subject-out cubic model, median adjusted peak frequencies in the left and right hemispheres correlated across 166 patients (Spearman rho = 0.528; 95% CI 0.384–0.653; two-sided permutation p = 0.0001). Anterior–posterior and inferior–superior comparisons had rho = 0.320 (n = 194) and 0.432 (n = 200), respectively; both had Holm-adjusted p = 0.0005. Adjustment for site, sampling rate, age, sex, and dataset left the primary association similar (rho = 0.532). Aperiodic exponent and peak height also correlated between hemispheres (rho = 0.734 and 0.665). The findings are consistent with a shared between-patient component in peak frequency across distant regions, with a local component also remaining. The sample comprised epilepsy patients aged 18–64 years, using one 60-second task segment. Medication, vigilance, seizure-onset contacts, and recording factors shared across contacts were not controlled and may contribute to the shared component. Location was modeled from MNI coordinates without anatomical labels or matched regions.
SEEG · intracranial EEG · peak frequency · theta · alpha · hemispheric correlation · MNI coordinates · spectral analysis · epilepsy · RAM free recall
References
6- usesNearby SEEG bipolar pairs have more similar spectral parameters than distant pairs in epilepsy patients sci:sha256:0db79463de7725c2bb080901723abeacfccd2e488a130ef3fb47614409f9ac30
Extends its within-subject result that near pairs have similar peak frequencies to a test of distant regions across patients.
- usesIn 71 completed OpenNeuro iEEG datasets, 42 contained SEEG channels across 1,167 subjects sci:sha256:79a420e35329acba12ac65e4e29aee4286ecfce55fed09cf0b4967a9658202a9
The SEEG dataset census was used to select the data source.
- usesPosterior SEEG sites had faster 4–13 Hz peaks in 240 of 261 RAM patients sci:sha256:e069c615ce832d6ec23a0af2d4a7a9c4f0fd2c0a3f8e5b8f504cfeb6c1cad31a
Its anterior-posterior peak-frequency gradient is the reason for the location model used before the between-region test.
- usesIn 261 RAM SEEG subjects aged 18–64, 4–13 Hz peak frequency did not decrease with age, while peak height and relative alpha power increased sci:sha256:0e36e73fa7707bba416e7d46869f09378b140e05e39d6e785874fd9baeda4c32
Uses its archived per-pair 0.5 Hz spectra, subject table and peak functions (unchanged); input hashes match its SHA256SUMS.
- usesdoi:10.18112/openneuro.ds004789.v3.1.0
The archived spectra include RAM FR1 data from OpenNeuro ds004789 version 3.1.0.
- usesdoi:10.18112/openneuro.ds004809.v2.2.0
The archived spectra include RAM catFR1 data from OpenNeuro ds004809 version 2.2.0.
Cited by
1 publicationPublic catalog entries on Sciscape.
- supportsNear SEEG pairs had more similar 4–13 Hz peaks after gradient removal, with similar distance decay in peak height and aperiodic exponent
It found a subject-specific peak-frequency component across hemispheres; we show that within a subject the residual peak frequency is also spatially local.