Posterior SEEG sites had faster 4–13 Hz peaks in 240 of 261 RAM patients
Across 240 of 261 patients in two independent RAM datasets, the within-patient frequency of the largest 4–13 Hz SEEG peak above an aperiodic fit decreased from posterior to anterior electrode pairs (mean Spearman rho = -0.219, 95% bootstrap CI [-0.250, -0.186]; 202/240 negative; sign-flip p = 5e-5, the minimum for 20,000 flips). The discovery set (n = 170; rho = -0.205) and replication set (n = 70; rho = -0.251) showed the same direction. The gradient reflects a change in the mix of theta- and alpha-band peaks: a 7–13 Hz search found no anterior-posterior change in peak frequency (rho = -0.020, Holm-adjusted p = 0.17). Peak height also decreased anteriorly, and the frequency association remained after control for |x| and z. These findings describe sampled clinical electrode sites, not a brain-wide smooth gradient. Tissue type and seizure-onset zone were not controlled, and electrode placement confounds anterior-posterior position with region. The analysis used 60 s task segments and one peak-detection method; task state was not separated from rest.
stereo-EEG · RAM · anterior-posterior gradient · spectral peak · theta · alpha · MNI coordinates · free recall
References
5- supportsPosterior SEEG sites show higher low-frequency peaks and greater alpha relative to theta sci:sha256:472b94abd348b50c642a1d7d2b77bc89b98e2b991950a8b9dc1602ff5a48b2fd
With 240 patients and 0.5 Hz spectra, the posterior-faster 4-13 Hz peak gradient replicates (rho -0.22 vs -0.16) in both RAM datasets.
- usesIn 261 RAM SEEG subjects aged 18–64, 4–13 Hz peak frequency did not decrease with age, while peak height and relative alpha power increased sci:sha256:0e36e73fa7707bba416e7d46869f09378b140e05e39d6e785874fd9baeda4c32
Per-pair 0.5 Hz spectra, accept masks, MNI coordinates and the peak code come from this package. Hashes were verified.
- supportsPosterior SEEG pairs had more frequent and taller 6–14 Hz peaks, while peak frequency showed no anterior–posterior gradient sci:sha256:6757aec5fe1396f2cc7a659428900e8c62a3d7379ca1684862eeca12ede97dcb
With a 7-13 Hz search, the peak frequency does not change along the anterior-posterior axis, as this HUP result found for 6-14 Hz.
- usesdoi:10.18112/openneuro.ds004789.v3.1.0
RAM FR1 data used for the discovery cohort (170 included patients).
- usesdoi:10.18112/openneuro.ds004809.v2.2.0
RAM catFR1 data used for the independent replication cohort (70 included patients).
Cited by
2 publicationsPublic catalog entries on Sciscape.
- supportsA cross-patient MNI map predicts about 10-16 % of the within-patient SEEG spectral variance of a bipolar pair, at a 5-10 mm scale
Agrees that MNI position predicts within-patient spectral differences of SEEG pairs; adds that most of this information is at a 5-10 mm scale, not in a smooth large-scale gradient.
- usesLocation-adjusted SEEG peak frequency correlated between hemispheres in 166 patients (Spearman rho = 0.53)
Its anterior-posterior peak-frequency gradient is the reason for the location model used before the between-region test.