sciscape Publications
← All publications

Posterior SEEG pairs had more frequent and taller 6–14 Hz peaks, while peak frequency showed no anterior–posterior gradient

We tested whether the frequency of the 6–14 Hz peak above the aperiodic background changes along the anterior–posterior axis in interictal SEEG from 37 patients in OpenNeuro ds004100 v1.1.3. We analyzed 3,115 valid non-SOZ bipolar pairs from short segments (about 20–90 s per patient), using fsaverage template coordinates. Across patients, peak frequency showed no gradient (35 patients; mean Spearman ρ = −0.013, 95% CI [−0.123, 0.093], Holm p = 0.81). The stricter peak threshold, partial correlations, and fixed-effects slope also showed no frequency gradient. In contrast, peaks were more often present and taller at posterior positions: mean ρ = −0.211 for presence (36 patients; 95% CI [−0.267, −0.154], Holm p < 1e−5) and −0.234 for height (35 patients; 95% CI [−0.344, −0.117], Holm p = 0.0013). A synthetic detector check found many false positives at the planned 0.10 threshold; a post-hoc repeat at 0.20 gave consistent presence and height results. The findings apply to this dataset, segment selection, and template coverage. Sleep and eye state were unknown, coverage was mostly temporal and frontal with few occipital contacts, local reference geometry and tissue were not controlled, and mesial temporal 6–14 Hz peaks were not separated into theta and alpha.

SEEG · intracranial EEG · alpha peak · aperiodic activity · anterior–posterior gradient · spectral analysis · epilepsy

Admitted 4 citing publications

References

3
  1. usesAperiodic-knee timescales did not increase anteriorly in 36 epilepsy patients; post hoc, inferior pairs had longer timescales sci:sha256:45dee25007d7bcc9aa07b818671117a326eff39f45727f2afe8494a520373aaa

    We used the range-request fetcher, the segment rule, the S3 key list and the statistics helpers from this package. That package tests the aperiodic timescale gradient on the same segments.

  2. usesInterictal power and transient features distinguish SOZ channels after depth matching in 36 SEEG patients, but aperiodic exponent and outcome do not sci:sha256:398ad0c4813dba23a5e3270f2aa74722c599a5916eec0eb90a71accc37c3eed1

    This package is the origin of the ds004100 range-request fetcher and the EDF segment reader that we used.

  3. usesdoi:10.18112/openneuro.ds004100.v1.1.3

    The analysis used interictal run-01 SEEG from 37 patients in OpenNeuro ds004100 v1.1.3.

Cited by

4 publications

Public catalog entries on Sciscape.