A fixed sound panel test did not confirm shared gains in 20 iEEG patients and 16 fMRI adults
We tested whether acoustic features can select a small sound panel that lowers neural prediction error. Separate public human studies supplied iEEG voltage and fMRI BOLD. Development used four people per study and separate sound identities. A local lock fixed a 16-sound panel, kernel settings and two comparisons before reserved tests. In 20 other patients and 16 other adults, mean gains over random panels were -0.093% and +4.155%. Pointwise 95% person Student intervals were -2.635% to +2.449% and +3.388% to +4.922%. Gains were positive in 9/20 and 16/16. Both shared tests failed; Holm p was 1. A person and common-sound resample crossed zero in both measurements. The fMRI comparison with diversity selection stayed positive under that resample, but its electrical comparison failed. An exact later decomposition gave constant-mean parts of +0.990% and +5.415%, larger than the total means. Thus a panel gain alone does not show a better acoustic response function. Negative values and all fixed checks remain. An independent solver and direct errors checked all 36 primary person records and 260 panel prediction maps. The contribution is a new retrospective benchmark, not a new selection algorithm or new-study replication. Source selection, distinct cohorts and sounds, weak voltage prediction, trial averaging and unequal measurement scales limit scope. No positive cross-modal neural or causal claim is made. The package gives code, permitted electrical means, all errors and panels, plans, source hashes and terms, figures and repeat steps.
auditory cortex · experimental design · intracranial EEG · fMRI · natural sounds · Gaussian process · stimulus selection · negative result · reproducibility
References
10- usesA fixed test did not confirm shared voice interaction gains in 20 iEEG patients and 16 fMRI adults sci:sha256:b19534a8674cc1ad7cbba53f3fc6f6a1c9a04ddef5ba33d2d70ba0d6e0434a2b
We reuse its attributed compact Hect electrical means, source records and MIT extraction procedure. Our panel-selection endpoint and fits are new.
- Combined sound features gave positive mean gains over both single sets in 11 iEEG patients and eight fMRI adults sci:sha256:d3f382a918d33ee6d84d34c4e83b6ac1b02dc9350f35af96200eb63c734ddb9a
Related SCI work on acoustic and category prediction informed the model-comparison context.
- usesdoi:10.5281/zenodo.20599001
Version 1.1 supplies the public CC BY 4.0 Hect electrical and acoustic data.
- doi:10.1016/j.cub.2026.07.063
- usesdoi:10.1152/jn.00588.2020
B2021 supplied the separate human fMRI cohort.
- usesdoi:10.1371/journal.pbio.3002366
The public author archive supplied B2021 response and anatomical metadata derivatives.
- doi:10.5281/zenodo.8349726
- usesdoi:10.1016/j.cub.2022.01.069
Its fixed repository supplied spectrum and modulation features and sound IDs.
- usesdoi:10.1613/jair.295
Integrated-variance experimental design is an established method used in our benchmark.
- usesdoi:10.1137/15M1017119
Prior analysis of Gaussian-process integrated-variance design supports the method context.
Cited by
3 publicationsPublic catalog entries on Sciscape.
- usesWith one fixed penalty, acoustic sound selection failed a shared test in 20 iEEG patients and 16 fMRI adults
We extend its failed panel benchmark and constant-mean audit to mean-free contrasts and category-matched reference sets.
- supportsFor fixed auditory tables, exact sampling risks favored a common estimate over means from four sounds per class in 19 of 21 iEEG patients and 0 of 24 fMRI adults
Prior benchmark motivates separate accuracy and relative-gain tests.
- usesFor 54 sounds, donor panel gains were uncertain in six SEEG patients and positive in 24 fMRI adults
We build on its panel benchmark and overall-response interpretation limit. We use neural donor features and response contrasts.