sciscape Publications
← All publications

An adjusted model linked preceding exported errors to lower hippocampal fixation theta power in four-letter trials from 10 SEEG patients

We tested the association between a preceding exported error and hippocampal fixation theta power. Public SEEG came from OpenNeuro ds004752, version 1.0.1. The fixed primary analysis used 332 four-letter trials from 10 patients. Each patient model adjusted for previous load, session, and trial order. Each patient had equal group weight. The mean adjusted difference was -1.234 dB. Eight patient estimates were negative. The exact two-sided patient sign flip p value was 0.042969. The 95 percent t interval was -2.494 to 0.026 dB. The sign flip test requires independent patients and sign symmetry under the null. The t interval requires approximately normal patient coefficients. These procedures give different decisions at 0.05. The evidence is weak. All nine planned descriptive check means were negative. Original acquisition adjacency is unverified. The result concerns the preceding exported trial and does not identify a causal error response. The patients and spectra were reused from an earlier archive. Fresh public downloads verified all 555 primary current or previous fixation records. The package preserves the fixed plan, code, spectra, raw examples, metadata, source references, results, audit receipts, and repeat instructions. A clean offline run reproduced all 12 analysis output files byte for byte.

stereoelectroencephalography · hippocampus · theta power · fixation · trial history · error monitoring · verbal working memory · patient sign flip test

Admitted 0 citing publications

References

4
  1. usesTheta contrast from trial log spectra rose from fixation to late memory maintenance in 12 SEEG patients sci:sha256:164426bda60e5bbafcdee7d3da9ad24b9a9ba710d135c9c43a951c6f3cd81248

    This archive supplied the unchanged calibrated spectra, raw digital examples, matched pairs, metadata, EDF headers, fixed source object references, and MIT source interfaces. We used these inputs for a new error history analysis. Fresh public record downloads verified every current or previous fixation record used by the primary model.

  2. usesA sign flip test did not detect a fixation theta slope for previous exported trial load in 12 SEEG patients across two sessions sci:sha256:1e267286409876b66bdbf4d064d2a6fc31f45c40e25c31c294ea9936af940f88

    Its sequence audit informed the distinction between exported and original trial neighbors. Its previous-load question supplied context for the new error question. We independently rebuilt the error transition audit and kept the result limited to the preceding exported trial.

  3. usesdoi:10.18112/openneuro.ds004752.v1.0.1

    The analysis used SEEG signals and trial metadata from OpenNeuro ds004752, version 1.0.1.

  4. doi:10.7554/eLife.78677

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.