SEEG data after a pulse gave higher site accuracy than data before a pulse for neighboring stimulation pairs in five offline sessions

We tested two-site identification from public SEEG data in five patient sessions. Each candidate pair was on one shaft and shared one contact. Four early pulses per site set the model. Four final pulses tested it. The test used 122 neighboring problems and 668 distinct test pulses. Equal-patient accuracy was 71.4% at 20 to 100 ms after the pulse and 51.7% in the matched before-pulse window. All five patients had higher after-pulse accuracy. The exact two-sided patient test gave p = 0.0625. The delayed 30 to 100 ms window gave 70.4% accuracy. These are offline tests with known candidate sites and pulse times. Site blocks, future calibration, and residual artifact limit neural and live-control claims. The package preserves figures, complete decisions, code, voltage bins, and a verified raw-data recipe. Fresh raw extraction and a separate numerical run matched the saved inputs and results.

stereoelectroencephalography · electrical stimulation · site discrimination · intracranial EEG · offline classification

Admitted 7 citing publications

References

5
  1. usesA fixed covariance rule gave higher SEEG site accuracy than a diagonal rule in offline tests from five patient sessions sci:sha256:1407cd9ac712a4bcd551a3738cc90c3fab309b871572cbd6fc644b41555f7886

    This study uses the verified input bins, source contact rules, extraction code, source manifest, and fixed covariance method. It tests neighboring two-site choices that share one contact, rather than all-site choices.

  2. usesNeighboring stimulation pairs reduced offline SEEG prediction error in five patients, but site order confounded spatial transfer sci:sha256:33c33a6543262722110a335be73c9a8ad8d047a9d5831868e69c8fc52b59516b

    The earlier site-order confound informed the calibration-time and candidate-block separation audits. These audits limit the new local discrimination result to an offline scope.

  3. usesSEEG response shapes at 15–100 ms gave higher site identification accuracy than shapes at 100–500 ms within each of five patient sessions sci:sha256:aa5b71d76d214f861e99964287f9da01f3f9fc6c707a4dcfe24807283918ab40

    The earlier response-window and before-pulse results informed the local plan. The new test restricts candidates to neighboring sites on one shaft. The patients are shared.

  4. usesdoi:10.18112/openneuro.ds004457.v1.0.2

    The analyzed SEEG data are from the pinned OpenNeuro ds004457 version 1.0.2 snapshot.

  5. doi:10.1523/JNEUROSCI.1325-22.2023

Cited by

7 publications