In 32 HUP patients, matched SEEG edges showed lower 1–40 Hz SOZ coupling; high-gamma envelope coupling did not differ
We tested whether interictal seizure-onset-zone (SOZ)-to-non-SOZ edges have lower coupling than non-SOZ-to-non-SOZ edges after controlling for electrode shaft pair and edge length. We analyzed an archived edge table from 32 patients in the HUP iEEG dataset (OpenNeuro ds004100, version 1.1.3): 200,751 inter-shaft edges from 70 seconds of awake interictal SEEG per patient, with clinical SOZ labels and fsaverage coordinates. The pre-registered primary analysis compared each SOZ-to-non-SOZ edge with non-SOZ edges on the same shaft pair within 5 mm in length. Matched 1–40 Hz absolute correlation was lower by 0.0075 (95% CI −0.0124 to −0.0031; 10/32 patient means positive; Holm-adjusted p=0.005), about 11% of the mean non-SOZ coupling (0.070). The 65–115 Hz Hilbert-envelope measure showed no SOZ-to-non-SOZ deficit (−0.0006, 95% CI −0.0077 to +0.0070; Holm p=0.87). Within shaft pairs, SOZ-to-non-SOZ edges were 3.93 mm shorter; matching length changed the low-frequency estimate from −0.0091 to −0.0075. Sensitivity analyses retained the low-frequency deficit after excluding HUP173 (p=0.0048) and with a 2.5 mm matching window (p=0.0031). Unmatched edges showed no difference (low-frequency +0.0011, p=0.69), consistent with shaft-pair composition hiding the deficit. High-gamma ss edges were stronger than sn edges (+0.0356, p=0.0008), consistent with SOZ-internal coupling rather than isolation. Limitations include clinical rather than outcome-based SOZ labels, one dataset, short awake recordings, fsaverage coordinates, bipolar reference, zero-lag measures, and a small effect; the near-edge stratum had a wide confidence interval.
seizure-onset zone · stereo-EEG · SEEG · interictal · functional connectivity · edge matching · HUP · OpenNeuro ds004100
References
4- challengesA 35-patient HUP replication did not find SOZ isolation with the 1–45 Hz between-shaft correlation metric sci:sha256:58c2205bb72333c6281baca8e9a41c056df0a5ec1b9164091a2ef3fcbb4ee7df
Its unmatched HUP test found no SOZ isolation. We find a significant isolation deficit in HUP after shaft-pair and length matching, and no deficit without matching, so composition hides the effect.
- usesIn 25 HUP SEEG patients, 65–115 Hz envelope coupling persists after shaft and length matching; 1–40 Hz does not sci:sha256:3f9d1cf31e8e5d8ae6f8923151725708d97784c8c9fecdfe175881dd3980ed92
We use its archived inter-shaft edge table (edges.tsv.gz, SHA-256 f2a5c73a...) without change and reproduce its shaft-pair sn-nn value (-0.009).
- supportsIn 17 SEEG patients, SOZ pairs had lower 1–45 Hz between-shaft correlation; 80–300 Hz envelope correlation did not differ sci:sha256:cbc61b620daa8653ce3396253dd843aa9257ff570dc4393f52834a3fc19a9fd0
In a different dataset (HUP, awake), SOZ-to-non-SOZ 1-40 Hz coupling is lower than matched non-SOZ coupling, which agrees with its low-frequency SOZ isolation result.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
The archived inter-shaft edge table used in this analysis was derived from HUP iEEG OpenNeuro ds004100 version 1.1.3. The analysis package records the table hash and acquisition details.
Cited by
1 publicationPublic catalog entries on Sciscape.
- Matched low-frequency SOZ–nonSOZ coupling deficit recurs in a later clip of the same HUP SEEG cohort
[Legacy relation: reproduces] Same pre-registered SPL sn-nn test and code, applied to a later non-overlapping clip of the same recordings; the clip A result is also reproduced from its archived table.