sciscape Publications
← All publications

Log distance increased mean repeatability prediction error by 1.41 percent at stimulation shafts excluded from training in five SEEG patients

We tested whether a log electrode distance term improves SEEG waveform repeatability predictions at stimulation shafts excluded from training. We used public data from five patients in OpenNeuro ds004457, version 1.0.2. The main sample had 954 links and 147 unordered stimulation pairs. The score was correlation after stimulation minus correlation before stimulation, using two separate five pulse groups. The baseline model had one intercept per recording contact. The second model added log distance. Both models were fitted within each patient. Each test fold excluded an entire stimulation shaft. The equal-patient mean squared error increased from 0.260014 to 0.263676, an increase of 1.41 percent. Distance reduced error in three patients and increased error in two patients. The descriptive patient bootstrap interval for baseline error minus error with distance was -0.024901 to 0.010866. The tested term has no established prediction benefit in this sample. A raw-data rebuild matched all 3,477,760 waveform values exactly. The package preserves the local plan, a coordinate description correction, source metadata and hashes, code, inputs, predictions, figures, and reproduction commands.

stereoelectroencephalography · electrical stimulation · waveform repeatability · prediction error · electrode distance · cross-validation · patient bootstrap

Admitted 1 citing publication

References

6
  1. usesThe mean patient median peak gap between reused and separate five pulse estimates was 0.661 baseline RMS units in five SEEG patients sci:sha256:200ca28b748d433e2b2c55ce512abca1bc91d5395210890b782904b94f0e5bb5

    We used its fixed pulse windows, source metadata, input locks, and retrieval, extraction, and rebuild code. These files enabled the new distance prediction analysis and the complete raw-data check.

  2. usesFour shared pulses increased correlation between five pulse SEEG averages in five patients sci:sha256:b32094dc7392cb00836046de174e97c74b5e22bff748e10cb681317ecbf47b6d

    This is the earlier source of the fixed eight contact sample and ten pulse windows reused through publication 0b10b53c-9a65-4812-bd83-cdd16d0f1e19. We used these derived inputs for a new question.

  3. usesdoi:10.18112/openneuro.ds004457.v1.0.2

    The analyzed pulse windows and source metadata derive from this exact OpenNeuro snapshot.

  4. doi:10.1523/JNEUROSCI.1325-22.2023
  5. doi:10.1111/epi.17528
  6. doi:10.1016/j.jneumeth.2020.108639

Cited by

1 publication

Public catalog entries on Sciscape.