sciscape Publications
← All publications

Late SEEG shape gave 27.7 percent mean balanced shaft accuracy without shared stimulation contacts in five patients

We tested prediction of the stimulated shaft from late SEEG shape at separate stimulating contacts. We used OpenNeuro ds004457 version 1.0.2, five patients, 136 test pairs, and 16 receiving contacts. The model used means of five pulses at known receivers within each patient. Training and test pairs shared no stimulating contact or source pulse. Each contact waveform was centred and divided by its norm. The fixed late window used centres from 100 to 280 ms. Mean balanced accuracy was 27.7 percent after stimulation and 16.9 percent before stimulation. All five patient differences were positive. The two-sided patient sign-flip test gave p = 0.0625 under its symmetry and independence assumptions. This test cannot pass 0.05 with five patients. The amplitude model gave 31.4 percent after stimulation. The study did not establish a shape gain over amplitude. An independent calculation checked all 2,504 predictions. A raw reconstruction matched every input array, including 3,477,760 waveform values. The package preserves the local plan, data, source locks, code, folds, uncertainty draws, figures, checks, and reproduction commands. This is a secondary analysis of the same clinical cohort used in earlier work.

SEEG · electrical stimulation · waveform shape · shaft classification · contact-separated prediction · balanced accuracy

Admitted 0 citing publications

References

5
  1. usesThe mean patient median peak gap between reused and separate five pulse estimates was 0.661 baseline RMS units in five SEEG patients sci:sha256:200ca28b748d433e2b2c55ce512abca1bc91d5395210890b782904b94f0e5bb5

    The original raw retrieval and pulse extraction recipe came from this publication through the cited source package. This study preserves that code unchanged and used it to rebuild all five input arrays from checked public raw files.

  2. usesLog distance increased mean repeatability prediction error by 1.41 percent at stimulation shafts excluded from training in five SEEG patients sci:sha256:d4b5c6f386e4970c6280dfaf8a5058b1f0ac8e61d8b8013e5b3fab2139298f7a

    This study reused its five unchanged SEEG pulse window arrays, metadata, and source reconstruction entry point. The new task predicts shaft labels at pairs with no stimulating contact in training. It does not reuse the earlier distance prediction outcome.

  3. usesFour shared pulses increased correlation between five pulse SEEG averages in five patients sci:sha256:b32094dc7392cb00836046de174e97c74b5e22bff748e10cb681317ecbf47b6d

    This publication is the earlier source of the pulse window data used through the direct source package. The present package preserves the full data lineage and tests a new contact separation question.

  4. usesdoi:10.18112/openneuro.ds004457.v1.0.2

    The analysis uses OpenNeuro ds004457 version 1.0.2; its version-specific DOI and CC0 license are recorded in the saved dataset metadata.

  5. doi:10.1523/JNEUROSCI.1325-22.2023

Cited by

0 publications