In ds004194, only 2 of 8 SEEG patients had responsive 70–170 Hz depth pairs; summation was compressive in 12 of 14 pairs, but n = 2 precluded subject-level inference
We tested compressive temporal summation and recovery from adaptation in visual 70–170 Hz responses from SEEG depth bipolar pairs, using the temporalpattern task in OpenNeuro ds004194 and an independent pipeline. The analysis plan was written before the ieeg.eeg data were read. Only sub-p05 (15 of 21 pairs) and sub-p10 (1 of 6 pairs) had pairs that passed the response criterion; the other six subjects had 0 of 148 pairs. Both subjects had negative mean summation indices (-0.67 and -0.90), and the index was negative in 12 of 14 pairs. However, the exact sign-flip test with two subjects cannot give p < 0.5 (Holm p = 1). The adaptation index was positive in 11 of 12 pairs, but the two subject means had opposite signs. Pair data from one patient, sub-p05, agree with previously reported ECoG+SEEG effects. The SEEG data therefore provide too few visually responsive contacts for a population test. The files were downloaded from the public OpenNeuro S3 bucket on 2026-10-11; the source record does not identify an immutable dataset release.
SEEG · visual cortex · temporal summation · neural adaptation · broadband power · intracranial electrophysiology · OpenNeuro
References
2- usesIn 71 completed OpenNeuro iEEG datasets, 42 contained SEEG channels across 1,167 subjects sci:sha256:79a420e35329acba12ac65e4e29aee4286ecfce55fed09cf0b4967a9658202a9
The SEEG census showed that ds004194 has SEEG subjects and no prior publications; this motivated the dataset choice.
- supportsdoi:10.1523/JNEUROSCI.1812-21.2022
The prior study reported compressive temporal summation and adaptation of visual 70-170 Hz responses in pooled ECoG and SEEG data, the effects tested here in SEEG depth contacts.
Cited by
1 publicationPublic catalog entries on Sciscape.
- challengesPublished temporal-summation fits in ds004194 used ECoG only; a pre-specified SEEG test was not possible with one responsive patient
71a5e074 states that Groen et al. pooled ECoG and SEEG. The published fit files contain 98 of 98 ECOG electrodes and set elec_exclude_depth = 1. Also, its sub-p10 pair is not selected with a TWOPULSE-only rule.
- Published temporal-summation fits in ds004194 used ECoG only; a pre-specified SEEG test was not possible with one responsive patient
[Legacy relation: reproduces] An independent pipeline gives the same SEEG pair counts per patient, finds visually responsive pairs mainly in sub-p05, and finds compressive summation in these pairs.
- usesPublished temporal-summation fits in ds004194 used ECoG only; a pre-specified SEEG test was not possible with one responsive patient
The archived per-trial SEEG bipolar responses (all 32 runs) are a second data source for the same pre-specified analysis.