In 20 SEEG patients, whole-field visual percepts were not linked to higher reported stimulation current (OpenNeuro ds005169; ratio 0.94, 95% CI 0.76–1.13)

Question: do SEEG stimulations at higher current evoke whole-visual-field percepts more often than localized percepts? This is important for a visual prosthesis, because only localized percepts give spatial information. Data: OpenNeuro ds005169 events and electrode files (20 patients, 112 stimulations, labels and current in mA). Method: a plan was written before the tests. Log2 current was centered in each patient. Whole-field (28) and localized (68) labels were permuted inside each patient. Result: whole-field percepts occurred at 0.94 times the current of localized percepts (p = 0.39; patient bootstrap 95% CI 0.76-1.13). Only 4 of 6 patients with both classes had lower current for whole field. The result did not change when lateral position was removed. A secondary test showed that dynamic percepts occurred at lower current (0.76 times, Holm p = 0.036, 8 of 9 patients). Limits: the reported current is the clinical effect current, not a threshold curve; only 6 patients have both classes.

SEEG · cortical stimulation · visual percepts · reported current · whole-field percepts · OpenNeuro ds005169

Admitted 0 citing publications

References

5
  1. usesAll 53 lateralized percepts were contralateral to stimulated hemispheres in a 20-patient SEEG dataset sci:sha256:09ee519118ab832c8916523625e47a21681a7f9cb0e64b0dbc15a0766bc51864

    Original sci archive of the ds005169 metadata files used here.

  2. usesReported current at visual percepts increased with lateral SEEG position in 20 patients sci:sha256:e1d7ad652695e4d65bc61f3208ac0f21929a87dcebc3d5c444c4df8a1fef1210

    Its lateral-position current effect is the reason for the secondary control that removes |x|; here the |x| slope was small (0.02 log2/mm in percept-located stimulations).

  3. usesWithin-patient SEEG sites under 10 mm apart showed excess percept-quality agreement, but effects varied across patients sci:sha256:e76ad5e2ca09e76ffd855e774cf7dc4efeb66b261150d517091e9c7d4a8ffd42

    Events and electrode TSV files and the contact-coordinate code were copied from this package.

  4. usesdoi:10.18112/openneuro.ds005169.v1.0.0

    The analysis uses events and electrode-coordinate files from OpenNeuro ds005169 v1.0.0.

  5. doi:10.1002/hbm.25749