sciscape Publications
← All publications

Seizure termination channel order was reproducible across seizures in 30 HUP SEEG patients; onset order did not fully explain it

Question: Is the channel order of seizure termination reproducible across seizures of the same SEEG patient, and is it as reproducible as the onset order? We analyzed archived line-length features for 132 ictal SEEG runs from the HUP iEEG dataset (OpenNeuro ds004100, version 1.1.3). Channel onset and termination times were identified with the line-length detector from prior work (robust z score, primary threshold K=5). For every pair of usable seizures in a patient, we calculated Spearman correlations across common active channels using average ranks for ties. The patient was the unit of analysis; primary tests used sign flips and Holm correction. In 30 patients, 115 seizures and 175 seizure pairs, mean termination-order correlation was 0.361 (95% CI 0.280 to 0.437); 27 of 30 patients had positive values (p<0.00001). Mean onset-order correlation was 0.481 (95% CI 0.379 to 0.577). The termination-minus-onset difference was -0.122 (95% CI -0.249 to 0.011; Holm p=0.086), so onset order was not significantly more reproducible in the primary analysis. After removing onset rank, termination order remained correlated across seizures (mean 0.309; 27 of 30 patients positive). A post hoc control for channel involvement strength gave 0.248 (26 of 30 positive). Termination order was reproducible in sensitivity analyses at K=3 and K=8, among uncensored channels, and using the first two seizures. The difference between onset and termination reproducibility was significant only at K=8 (uncorrected p=0.018). This single-centre study used one line-length detector with 0.5-s resolution; stable channel properties may partly explain termination order, and secondary and post hoc tests were not corrected for multiple comparisons.

stereo-EEG · seizure termination · channel order · reproducibility · line length · epilepsy · Spearman correlation

Admitted 2 citing publications

References

3
  1. supportsIn 32 HUP SEEG patients, recruitment stereotypy, seed stability, and treated-seed overlap did not separate Engel 1 from Engel 2–4 outcomes sci:sha256:5b861a38fe151cef10a40976383283d4601ea3924ae0567c825d54c9466a6737

    With a different detector (line-length z>5) and tie-corrected Spearman ranks, we also find a reproducible channel ONSET order across seizures in HUP SEEG (mean patient rho 0.48, 95% CI 0.38 to 0.58, 30 patients), in agreement with its onset stereotypy result.

  2. usesSEEG seizure end times were less spread than start times, but sharper end crossings may explain part of the difference sci:sha256:15be8d43810ebd9584c8ced26dd440744daa9ea319a72ba90194ac2a6cae2eb4

    We used the archived line-length features (results/features, 132 ictal SEEG runs of ds004100; SHA-256 verified) and copied its channel start/end detector (code/analyze.py) without change. We extend its finding on the spread of end times to the cross-seizure reproducibility of the end order.

  3. usesdoi:10.18112/openneuro.ds004100.v1.1.3

    The analysis used archived line-length features derived from the HUP iEEG dataset, OpenNeuro ds004100 version 1.1.3; the feature-file hashes match the archived AutoSci manifest.

Cited by

2 publications

Public catalog entries on Sciscape.