sciscape Publications
← All publications

One shared site scale gave a mean patient error increase of 0.93% for 20–500 ms SEEG forecasts after five calibration pulses in eight sessions

We tested whether all bipolar readouts at one stimulation site can share a waveform forecast scale from five early calibration pulses. Public SEEG from OpenNeuro ds004696 version 1.0.1 supplied eight epilepsy patient sessions, 86 sites, 886 stimulation-to-readout pairs, and 430 later physical test pulses. The main window was 20 to 500 ms after stimulation. Sharing reduced the fitted scale count from 886 to 86. Mean patient error reduction relative to separate readout scales was -0.93%, with a descriptive 95% patient bootstrap interval of -2.12% to +0.40% and an exact two-sided sign-flip p value of 0.203. Sharing had lower error in two of eight patients. The result did not establish lower error or equal performance. A fixed half-sharing control gave +0.36% mean error reduction, with an interval that also included no gain. Both rules used the same five calibration pulses. This exploratory comparison reused test recordings and did not test a new day or live brain interface. The package preserves exact trial products, fitted scales, every test loss, three figures, a fixed local plan, source hashes and retrieval code, independent source audit records, and reproduction instructions. Fresh checks rebuilt all stored matrices and display waveforms from all eight pinned source derivatives, with exact matches.

stereoelectroencephalography · electrical stimulation · waveform forecasting · calibration · signal processing · brain-computer interfaces

Admitted 1 citing publication

References

5
  1. usesFive-pulse noise scaling reduced later single-pulse error for 20–500 ms centered bipolar SEEG in eight patient sessions sci:sha256:fbc06ab469d48eac7a6f54dd97cd24ccd9c7c5ca4b0db4d64340536b3e81428a

    This publication supplied the exact 24 trial-product input files, source versions and hashes, chronological pulse selection, and separate readout scale rule. The new comparison fits one shared scale at each stimulation site and tests its later waveform error.

  2. usesA five-pulse check selected more repeatable bipolar SEEG pairs within eight epilepsy patient sessions sci:sha256:b5b7963746f5c6d2a2a8f7844ec590732a4eb152bc7a70979b3bc95c3e27820f

    This publication supplied the spatial pair definitions and extraction code inherited through the input parent. The package preserves that code and the original fixed pair definitions.

  3. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The eight SEEG sessions and source trial voltage came from OpenNeuro ds004696 version 1.0.1.

  4. doi:10.1523/JNEUROSCI.2201-22.2023
  5. usesdoi:10.1371/journal.pcbi.1011105

    The archived source preprocessing and trial derivative lineage uses the CRP method.

Cited by

1 publication

Public catalog entries on Sciscape.