In 20 SEEG patients, learned channels did not detect seizures earlier than clinical SOZ channels
We compared seizure detection from 1, 2, 4, or 8 bipolar pairs selected from a patient’s other seizures (LEARNED), clinical seizure-onset-zone (SOZ) pairs, random pairs, all implant pairs, or the best pairs of the test seizure (ORACLE). We used archived 1-s high-frequency power (hp) and line-length (ll) features from 77 seizures in 20 patients at one center (HUP; OpenNeuro ds004100 v1.1.3). With hp and k = 4, LEARNED latency was 6.19 s and SOZ latency was 5.94 s (difference +0.26 s; 7/20 patients faster with LEARNED; p = 0.84). Both were about 3 s faster than random pairs. LEARNED and SOZ were not different at any tested k or with ll. LEARNED was 3.2–6.1 s slower than ORACLE across k = 8–1, consistent with the best pairs changing between seizures. More channels improved detection speed but increased sham detections; all pairs detected at −0.4 s and had a sham detection in 46% of seizures. A causal selection using only earlier seizures (57 test seizures) was also not different from SOZ (−1.02 s; p = 0.50). Limits include one center, clinical onset marks and SOZ labels, short pre-ictal sham data, 1-s resolution, one detector threshold, and run order used as seizure order. The analysis plan was written before results were computed. See the main text for methods, full results, and limitations.
SEEG · seizure detection · responsive neurostimulation · channel selection · intracranial EEG · epilepsy
References
5- usesOne-seizure SEEG onset maps predicted later onset pairs in 20 patients sci:sha256:67ad8d229163793857c7e18fb1ba4fc4ca4fd1d3f7e275852131f30b0a6198b6
Original extraction of the 1-s hp and ll features and the provenance file with EDF ETags.
- Four-pair seizure detectors showed similar detection for seizure-1 onset and clinical SOZ pairs sci:sha256:c2cd3c96ad4f2e2241ac721eddec521237522ea466a38d71ff1d28ce3298e3be
[Legacy relation: reproduces] Same question (few onset pairs from other seizures vs clinical SOZ pairs) on the same patients. We used a different detector (z >= 3 for 3 s, not 5 SD for 2 s), leave-one-seizure-out selection, a latency outcome and k = 1-8. The result is the same: no difference from SOZ, about 3 s faster than random pairs, much slower than the pairs of the test seizure.
- usesA second SEEG shaft was recruited a median 3 s after the first pair in 76 seizures from 22 patients (ds004100; 1-s HF power, z >= 3 for 3 s) sci:sha256:812b03f378a0b2439b900d992eead21cc505e616ba3752bb8e5684e96c4949d2
We copied the archived feature files from this package and used its detector rule (z >= 3 for 3 windows, baseline [-40,-25) s).
- supportsIn 20 HUP Patients, Few-Pair Detectors Were Faster on SOZ Contacts, but Full Non-SOZ Sets Matched Them sci:sha256:a16aaa8d88006807165a5e6d81824a0e567acebdeb7e3b9a8f07a31f94b1098f
With few pairs, SOZ pairs detected earlier than random pairs, and the difference became smaller with more pairs (k = 8), as ff35040d found for SOZ vs non-SOZ sets.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
Source dataset snapshot for the archived 1-s features and participant information used in the analysis.
Cited by
0 publicationsPublic catalog entries on Sciscape.