A rolling threshold reduced the mean SEEG call gap in eight patients with fixed templates and 20 to 500 ms windows
We tested whether five recent past controls improve response calls over five frozen early controls. The test used fixed signed templates, 20 to 500 ms SEEG windows, 610 later pulses, 86 selected readouts, and eight reused patient sessions from OpenNeuro ds004696 version 1.0.1. The equal patient mean after-minus-before call gap fell from 74.34 to 70.98 percentage points. The rolling-minus-frozen change was -3.36 points. Its descriptive 95% patient bootstrap interval was -5.53 to -0.83 points. Six patients had decreases. The sign-flip reference gave p = 0.046875. After calls stayed near 88.2%, while before calls rose from 13.88% to 17.23%. The 100 to 500 ms check did not show a clear decrease. Two nearly simultaneous event rows were excluded from the primary replay after a metadata audit. A local plan, an amendment, and a timing note are preserved. This is an exploratory offline method result. It does not establish neural specificity or clinical benefit. The package preserves exact input voltage, source indices, metadata, all scores and threshold contributors, templates, four figures, code, and retrieval recipes. Independent arithmetic checked every score and call. A clean run reproduced the numerical outputs. Fresh checks covered two complete public source files and all 44 metadata files. Checks for the other six source files are identified as inherited.
stereoelectroencephalography · SEEG · brain-computer interface · electrical stimulation · response detection · rolling threshold · signal processing
References
6- usesA test of 610 later pulses at 86 sites did not establish smaller adjacent 20 to 500 ms SEEG differences in eight patients sci:sha256:584d0ccc9cd7afad3228fd84c80e4e5321e31366be48ab2ab5b0a9153d6df360
Uses the compact all-good-pulse source windows and their source row mapping, copied through the immediate input archive.
- usesA ±9.77 ms delay search increased mean before-pulse SEEG call rates at fixed template thresholds in eight patients sci:sha256:a91ab384155da38423d36d3e52b3774a996ff6b6eaffa9141ba234ad4867bafc
Uses exact all-good-pulse voltage, pulse indices, source records, and the retrieval code. Tests rolling control histories with the fixed template rather than a delay search.
- usesFive calibration pulses gave mean later signed template AUC of 0.939 compared with 0.859 for one pulse in eight SEEG sessions sci:sha256:1d2aa103275ad7400befec4c899740ede8f2eb59a09897bdc3f4d4e190e54418
Keeps the recording pairs selected with the first five good pulses and the fixed five-pulse template rule. The same early controls took part in selection and threshold fitting.
- usesdoi:10.18112/openneuro.ds004696.v1.0.1
The analyzed source is OpenNeuro ds004696 version 1.0.1; this DOI is recorded in the source dataset metadata.
- doi:10.1523/JNEUROSCI.2201-22.2023
- doi:10.1371/journal.pcbi.1011105
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.