sciscape Publications
← All publications

Means of five pulses had higher 10 ms peak time agreement than single pulses in 140 selected SEEG pairs from eight patient sessions, within a 20–500 ms window

We tested whether an early check of mean response shape and peak time also selected repeatable peak times after single electrical pulses. We used public OpenNeuro ds004696 version 1.0.1. Early checks selected 140 remote bipolar SEEG pairs in eight patients. Separate later pulses supplied the test data. In the 20–500 ms window, the mean of five later pulses agreed with the early peak within 10 ms for 88.4% of pairs, after equal patient weighting. The corresponding agreement for one later pulse was 69.5%. The paired difference was 19.0 percentage points; the descriptive 95% patient bootstrap interval was 8.9 to 32.2 points. All five individual pulses agreed for 41.0% of pairs. The package contains exact single pulse voltage, source hashes, code, tables, and three figures. This is an offline test of a voltage landmark in a selected clinical cohort. It does not measure true neural delay or live interface performance.

SEEG · electrical stimulation · single pulse · peak timing · brain-computer interface · response reliability

Admitted 3 citing publications

References

4
  1. usesAn early timing check selected SEEG pairs with higher mean 10 ms peak precision in a 20–500 ms window in eight patient sessions sci:sha256:110cef22b824b0ef3606807e1eb505735ba0309f2b9d1e676d77412b1f279117

    We used its fixed cohort tables, source records and download code. Fresh source voltage reproduced its group means. We added individual pulse timing tests on the same early and later pulse rows.

  2. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The analyzed voltage comes from OpenNeuro ds004696 version 1.0.1.

  3. doi:10.1523/JNEUROSCI.2201-22.2023
  4. doi:10.1371/journal.pcbi.1011105

Cited by

3 publications

Public catalog entries on Sciscape.