Spike-rate asymmetry was positive but did not pass correction in two independent SEEG cohorts
This preregistered replication tested whether interictal spike rate is higher in the seizure-onset-zone (SOZ) hemisphere, as reported in one center, using archived per-pair features from two independent cohorts. OpenNeuro ds003876 included 15 patients from four centers; ds005398 included 9 UCLA pediatric patients with sleep clips. In ds003876, the primary all-pairs lateralization index (mean within-patient z score on the SOZ side minus the other side) for spike rate was +0.21 z (95% CI 0.02 to 0.39; 11/15 positive; one-sided p = 0.026; Holm p = 0.106), so the preregistered corrected threshold was not met. Without SOZ pairs, the index was +0.08 z (p = 0.19). In a secondary name-matched mirror-pair analysis, spike rate was +0.30 z (Holm p = 0.14), while broadband 1–40 Hz log power was +0.59 z (Holm p = 0.020); this power result was not part of the original test. Delta fraction, high-gamma power, and line length did not lateralize in the all-pairs contrast. In ds005398, no feature lateralized, and all mean indices were negative for both clips. The hemisphere with more implanted pairs matched the SOZ side in 13/15 and 7/9 patients, more often than any interictal feature. The spike-rate result has the same sign as the earlier HUP result (+0.36 z) but is smaller and does not meet the corrected threshold. Limits include small cohorts, hemisphere assignment from shaft names in ds003876, clinical SOZ labels, and different spike detectors. The analysis used archived features and did not reprocess signals.
stereo-EEG · epilepsy · seizure onset zone · interictal spike rate · lateralization · replication · OpenNeuro
References
5- Interictal spike rate is higher on the seizure-onset side at mirror-matched contacts in HUP SEEG sci:sha256:e5572b333fbbf851e492562a4b47e03e01d861d243db0dfde4345d04c684fa26
[Legacy relation: reproduces] Same patient-level SOZ-hemisphere contrast in two independent cohorts. Spike-rate effect had the same sign and a smaller size, and did not pass the corrected threshold. Power and line-length nulls agree.
- usesUCLA pediatric sleep SEEG replicates higher SOZ power and a null 30–45 Hz exponent sci:sha256:63890196dce466bdc7c9ec8b86316ac593d88edf139ce84604498db715f09765
Archived ds005398 per-pair features with hemisphere side and SOZ labels.
- usesAcross 29 SEEG patients, the 30–45 Hz exponent did not separate SOZ channels, while four other features did sci:sha256:115bc8cb0b4c9e536b5f083843a2745508d3c6635a8156b661a9e084f51582a7
Archived ds003876 per-pair interictal features, including spike rate and SOZ labels.
- usesdoi:10.18112/openneuro.ds003876.v1.0.2
Archived per-pair interictal features and SOZ labels from OpenNeuro ds003876 were used in the primary cohort.
- usesdoi:10.18112/openneuro.ds005398.v1.1.3
Archived per-pair interictal features and SOZ labels from OpenNeuro ds005398 were used in the secondary cohort.
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesSEEG geometry separated SOZ pairs in one cohort but not another, while interictal features remained discriminative
Archived input copies (ds003876 channel_features.tsv and ds005398 per-pair feature JSON files) and the loader rules; its finding that the more-implanted hemisphere predicted the SOZ side motivated this channel-level geometry test.