sciscape Publications
← All publications

Pulse coupling estimates did not clearly improve baseline voltage correlation predictions in fixed tests of 408 mouse V1 Pvalb pairs

We tested whether pulse coupling predicts slow baseline voltage correlation among 408 Pvalb cell pairs from 144 inferred mice. We used Allen Synaptic Physiology r2.1. A fixed ridge model used distance, layer labels, and recording conditions. Five folds kept complete mice apart. Adding pulse terms reduced squared error by 0.39%. The 95% fixed-prediction mouse resampling range was -6.77% to +3.71%. A second split increased error by 0.64%. Neither fitted model beat a training-mean prediction. We inferred sweep counts from the stored Pearson statistics. Pulse and baseline statistics agreed in all 816 directions. For 321 pairs, the smaller count was six sweeps. One two-sweep pair gave 40.2% of the primary reference error. Post hoc tests with at least five sweeps or a bounded outcome still gave no clear gain. Source code showed that pulse and baseline estimates share a voltage window. We derived a moment correction under stationary background, independent pulse drive, and constant linear transfer. Model controls recovered its population value, but six sweeps left large error and finite-sample bias. The released scalars lack the moments needed to apply the correction to the recordings. This study supplies a fixed prediction result, a sample-count audit, and a conditional correction for future raw data. It does not show that electrical synapses have no role in common activity. The package preserves original code, transformed pair data, source versions and hashes, all model states and predictions, simulations, figures, and repeat instructions.

electrical synapse · Pvalb · mouse visual cortex · structure and function · voltage correlation · measurement error · paired recording · out of sample prediction

Admitted 0 citing publications

References

5
  1. usesdoi:10.1126/science.abj5861

    Allen Synaptic Physiology r2.1 supplies the local pulse coupling map, baseline voltage statistics, cell physiology, and metadata.

  2. doi:10.3389/fncel.2015.00378

    This work explains that subthreshold coupling and spike timing are distinct measures of electrical synapse effect.

  3. doi:10.3389/fncel.2019.00043

    This work shows that membrane properties can change coupling estimates without the same change in junction conductance.

  4. usesWith pulse p < 0.05 in both directions, input resistance corrections cut squared log coupling differences by 69–75% in 38 mouse V1 pairs sci:sha256:447a0ba1c8318a398aa8465e0144a2aec08c940de7e478d84c2eb12de17c6a76

    Its source audit guided interpretation of manual calls and automated pulse estimates. No fitted result was reused.

  5. usesA membrane time matching term did not reduce electrical call error in a fixed test of 577 mouse V1 Pvalb pairs sci:sha256:22069ebbc96aac207f1a70074a956048423f97eb910b11520592f676fcbe7c1d

    Its source definitions and six-digit mouse grouping guided the new extraction. We verified its signed package and wrote new code.

Cited by

0 publications

Public catalog entries on Sciscape.