A scale update had lower geometric mean error than half-size pulse forecasts and higher error than zero in eight SEEG sessions at 20–500 ms
We tested one new calibration pulse after a recorded contact order change. Five old pulses supplied the response template. Four later pulses supplied the measured target. We used public STReEF SEEG data from eight people, 96 fixed conditions, and 6,803 stimulation-to-readout instances. At 20 to 500 ms, the update gave 26.5% lower geometric mean error than a fixed half-size new-pulse forecast. The error ratio was 0.735, with a descriptive 95% person bootstrap interval of 0.713 to 0.756. All eight person ratios were below one. The update error was 3.9% above zero-forecast error on this score. Its ratio to zero was 1.039, with an interval of 0.924 to 1.144. An arithmetic energy score gave a different result. The gain over the half-size pulse was larger before stimulation. A projection proof and a numerical control show how noise reduction can give a comparative gain without useful response prediction. This exploratory offline test does not establish neural artifact removal or a live BCI gain. The package preserves source code, figures, every instance error, version pins, hashes, and reproduction instructions. A full raw rebuild verified all 960 ranges and matched all input arrays exactly. A fresh analysis repeated the results and figures exactly.
SEEG · stereoelectroencephalography · intracranial EEG · brain-computer interface · waveform forecasting · template update · electrical stimulation · STReEF · OpenNeuro · forecast error
References
5- usesFive direct calibration pulses gave lower voltage size prediction error than an earlier reverse measurement in seven SEEG sessions sci:sha256:12309876475890f517cc321e1459a68ba3a8ad6a42054ad3d9f4a8a5e33c5e3c
Uses the earlier pulse-budget comparison to motivate direct new-pulse and prior-template baselines. The current study tests contact order reversal in STReEF. It does not use the earlier study data or code.
- usesA five-pulse check selected SEEG pairs with 60.8% mean shape agreement after contact order reversal at 20 to 500 ms in eight sessions sci:sha256:35cdaeabceeac5a3be97a54a264240386954c3bac2e4558f03b24d86d28e2bee
Uses the fixed 96-condition sample, exact pulse products, source records, and metadata selection and retrieval code. These inputs enabled a new chronological forecast test. The package credits all inherited files and code.
- usesdoi:10.18112/openneuro.ds005448.v1.0.0
The publication analyzes the 1.0.0 STReEF release of OpenNeuro dataset ds005448; saved source metadata identify this exact release and declare CC0.
- doi:10.1016/j.ynirp.2025.100274
- doi:10.1007/s12021-022-09567-6
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesEarly repeatable readouts accounted for 74 percent of mean SEEG error reduction against zero at 20 to 500 ms in eight patients after contact order reversal
Its results for a later pulse scale update motivated the half and zero forecast comparisons. Its early waveform agreement screen also informed the fixed secondary threshold. The current fitted scale uses five early pulses only.
- usesEarlier reverse templates had higher mean error than scaled two-pulse local forecasts in seven limbic SEEG sessions at 20 to 500 ms
We use its projection forecast context and distinction between denoising gain and error below zero to interpret the controls. Its data and code are not inputs.