In 13 HUP SEEG patients, a recording and state change added no large error to SOZ AUCs, while differences between patients were larger
We compared archived per-patient seizure-onset-zone (SOZ) area-under-the-curve (AUC) tables to estimate error from 30-s windows within a session (4 patients), two 70-s interictal clips (13 patients), and a 120-s cognitive-task recording versus an interictal clip (13 patients), relative to between-patient spread. For line length, error SDs were 0.029, 0.042, and 0.028, respectively; between-patient SD was 0.195. For high-frequency power, the corresponding values were 0.039, 0.046, and 0.034; between-patient SD was 0.190. The ratio of recording error to clip error was 0.66 (bootstrap 95% CI 0.47–0.86) for line length and 0.74 (0.51–1.04) for high-frequency power. Both met the prespecified criterion for no large added error (upper CI limit <1.5). Mean task-minus-interictal AUC differences were +0.008 (sign-flip p=0.50) and +0.014 (p=0.33), respectively. More than 94% of the variance of one per-patient AUC value was between patients. This is a synthesis of archived AutoSci tables, not a new signal analysis. The recording comparison used longer segments and a different pipeline than the clip comparison, so ratios below one may reflect segment length. The 30-s window estimate includes only four patients, the high-frequency bands differ between sources, pair-sampling error is not included, and the 13-patient bootstrap intervals are approximate. Dataset release versions for the analyzed files were not established.
stereo-EEG · seizure onset zone · AUC · line length · high-frequency power · measurement error · patient variability · epilepsy
References
5- usesIn 13 HUP patients, bipolar SEEG markers showed similar SOZ separation in awake task and interictal recordings, with pair ranks agreeing across datasets sci:sha256:2d48b2409d068d9bcead2d6fd6f05da31f63ddcbb8efb42a935c3b41f3d32674
Per-patient AUCs of ds005624 task and ds004100 interictal recordings with the same pairs (E_rec).
- usesIn 36 HUP SEEG patients, band-power and line-length SOZ AUCs repeated across two 70 s clips, but spike-like-rate AUC was less reliable sci:sha256:1ade2496a074e1d552641767ab2575b1cee1abee19d41b3db6c77b86d0beb92e
Per-patient AUCs of two ds004100 interictal clips (E_clip).
- usesA 12-window plan and tested code define, but do not measure, SOZ AUC stability in 13 HUP SEEG recordings sci:sha256:80dddd13583f6dd0a5bf9e39b34b5e57bab5917560eb113c2a730862fa5b860b
Gives the question context; this work answers a related error-budget question with archived data, not the 13-patient window test.
- supportsIn four HUP patients, 30-second SOZ AUC windows were usually within 0.05 of the six-minute estimate sci:sha256:ef5b73a42e68980a01139ea8693ea3588d35dc61297bb00b068285243841f658
Time and state error of per-patient AUC is small compared with between-patient spread in 13 patients, as fee9ecc0 found in 4.
- usesIn four HUP patients, 30-second SOZ AUC windows were usually within 0.05 of the six-minute estimate sci:sha256:ef5b73a42e68980a01139ea8693ea3588d35dc61297bb00b068285243841f658
Per-patient 30-s window AUCs of 4 patients (E_win30).
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.