Independent ±3 dB epoch power gains reversed the Fz theta-to-alpha CLN3–HV contrast using 95 ds008896 records’ first 20 epochs
We tested how epoch power scale affects a pooled EEG theta-to-alpha group contrast. The input was ds008896 version 1.0.1, with 32 CLN3 records and 63 healthy volunteer (HV) records. The primary score used the first 20 retained four-second epochs, an Fz reference, and mean posterior channel power. Theta was [4,8) Hz. Alpha was [8,13) Hz. The observed CLN3 minus HV contrast was +0.167018 log10 units. We allowed independent epoch power gains from 10^(-3/10) to 10^(3/10). Each gain multiplied both bands and preserved the epoch ratio. The sharp contrast limits were -0.115497 and +0.441498. Gain witnesses attained both limits. Zero was first allowed at a symmetric limit of 1.77046191 dB. The mean epoch log-ratio contrast was +0.100355 and remained unchanged. All six fixed analysis rules permitted both signs at 3 dB. We supply a proof, a reusable calculator, verified spectra, gain witnesses, bootstrap samples, and a locked source retrieval recipe. Fresh source files rebuilt all archived arrays exactly. Independent solvers and exhaustive small cases checked the limits. A clean run matched every numerical output hash. These are exact sample limits under the stated gain model. They do not show that these gains occurred in the recordings. The parent baseline results were known when the test was chosen. No age or clinical adjustment was possible.
EEG · theta-to-alpha ratio · sensitivity analysis · epoch power · CLN3 disease · healthy volunteers · linear fractional programming
References
4- usesThe 95% interval included zero for the Fz versus 19-channel mean change in the CLN3 versus volunteer theta-to-alpha contrast using 80 seconds per person in 95 ds008896 records sci:sha256:c7168c6fd457a7c40b234b7dcdd5819e4d60536686faad4c4b6a97efb9e77a6d
The 95 verified spectral archives, source metadata, locked file manifests, and extraction and retrieval code supplied the inputs for the new gain-bound test. We knew the parent baseline results before choosing this test. We retrieved all source EEG files again and rebuilt every archived array. The new result uses the same people and is not an independent cohort confirmation.
- usesdoi:10.18112/openneuro.ds008896.v1.0.1
The analysis used 32 CLN3 and 63 healthy volunteer records from OpenNeuro ds008896 version 1.0.1. The source has a CC0 license.
- doi:10.1002/nav.3800090303
- doi:10.1016/S0378-3758(01)00181-1
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesTemporal halves increased squared disagreement 2.76-fold for EEG theta-to-alpha scores in 95 ds008896 v1.0.1 records
After the primary analysis, its common within-epoch power-gain model informed an added algebraic interpretation. The model leaves each epoch ratio, and thus our primary temporal and exact random quantities, fixed. It did not supply the primary split test.