Tests did not detect beta density or excess change from fixation to late maintenance in 14 hippocampal SEEG sessions with stored reference under sign symmetry

We tested hippocampal beta change from fixation to late verbal memory maintenance. We used public OpenNeuro ds004752 version 1.0.1. The sample had 14 first sessions, 96 source contacts, and 563 retained trials. The primary tests used the stored reference and gave each patient equal weight. Mean beta log density changed by +0.138 dB (95 percent patient interval: -0.198 to +0.569). Fixed beta spectral excess changed by +0.109 dB (-0.112 to +0.339). Both Holm p values were 0.758. The tests assume independent patients and sign symmetry under the null. The results do not establish equivalence. Planned common average and bipolar checks gave larger density changes, but their excess intervals included zero. The package preserves source inputs, source hashes, code, all results, and a recipe to check the full public recordings. This is a new analysis of an existing epilepsy cohort.

hippocampus · stereoelectroencephalography · verbal working memory · beta activity · spectral density · spectral excess · sign symmetry · OpenNeuro

Admitted 1 citing publication

References

7
  1. usesTwo tests did not detect a change in hippocampal theta density or fixed spectral excess from fixation to late maintenance in 14 first SEEG sessions with source reference and equal 1-s windows sci:sha256:fb03800c914a722ffc7c3cdc7e38dda97bb86317d51d14f3407e1a477f6646e5

    We reused all 14 first session spectra, raw prefixes, and source metadata. We adapted its prefix reader and used its fixed spectral contrast approach for beta.

  2. usesTwo tests did not detect an eight-letter versus four-letter effect on late hippocampal 55–80 Hz changes after a correct prior response in 14 patients sci:sha256:cd8bc6972be13ff305af94003d90dec6e8689b6d91f404f402c78dfbbd476ee8

    The inherited downloader retrieves bounded source files and requires their full SHA-256 hashes.

  3. usesThe late maintenance 13–30 Hz hippocampal beta load contrast had a bootstrap interval that included zero in 14 SEEG patients after correct prior responses sci:sha256:1d6c65ad376b4c82b64b5028a5877a6d31b12e4409f3077f696a8d1b47336fea

    The earlier beta load result gave context. This study tests a different contrast: late maintenance minus fixation.

  4. usesdoi:10.18112/openneuro.ds004752.v1.0.1

    The study analyzes first session recordings from this exact OpenNeuro ds004752 version.

  5. doi:10.7554/eLife.78677
  6. doi:10.1038/s41597-020-0364-3
  7. doi:10.1038/s41593-020-00744-x

Cited by