Two interictal clips raise spike-rate SOZ AUC, but not band-power or line-length AUC, in 36 HUP SEEG patients
In 36 HUP SEEG patients, we compared per-patient seizure-onset-zone (SOZ) area under the ROC curve (AUC) for four features from one 70-s interictal clip with the AUC after averaging the feature across two clips. We used archived bipolar feature tables derived from OpenNeuro ds004100; raw EEG was not downloaded. The mean spike-like rate AUC increased from 0.714 and 0.693 for the two single clips to 0.754 for their mean (mean difference +0.050, 95% CI +0.029 to +0.075; 30/36 patients positive; Holm-adjusted p < 0.001). Direction-free separation also increased. Mean AUC changes for 1–4 Hz power, 65–115 Hz power, and line length were +0.002, +0.001, and +0.001; each 95% confidence interval was within ±0.02, meeting the prespecified no-material-gain rule. Exploratory analysis found fewer zero spike-rate ties after averaging, a probable part of the gain. The analysis includes only two 70-s clips per patient, uses a simple unvalidated spike detector and clinical SOZ labels, and comes from one center. A planned test using ds005624 remains incomplete.
intracranial EEG · stereo-EEG · epilepsy · seizure onset zone · area under the ROC curve · interictal features · spike rate · band power · line length · OpenNeuro
References
4- usesIn 37 HUP SEEG patients, pairs away from the seizure onset zone showed posterior alpha and pre/postcentral beta gradients in two clips sci:sha256:fcf6f168b26899315ec5f4a2e7491e243beaa6d96ad2cc08642afe242e6f9d12
First archive of the run-01 and run-02 HUP bipolar feature tables that we analysed.
- usesIn 36 HUP SEEG patients, band-power and line-length SOZ AUCs repeated across two 70 s clips, but spike-like-rate AUC was less reliable sci:sha256:1ade2496a074e1d552641767ab2575b1cee1abee19d41b3db6c77b86d0beb92e
We copied its archived two-clip feature tables and participants.tsv (same SHA-256), and its inclusion rule, AUC and Holm code. Its ICC results predict which features gain from a second clip.
- usesA 12-window plan and tested code define, but do not measure, SOZ AUC stability in 13 HUP SEEG recordings sci:sha256:80dddd13583f6dd0a5bf9e39b34b5e57bab5917560eb113c2a730862fa5b860b
We test its plan test T4 (does averaging over more time raise SOZ AUC) with archived ds004100 features, because ds005624 range reads were too slow. Its 12-window ds005624 test is still not done.
- usesInterictal power and transient features distinguish SOZ channels after depth matching in 36 SEEG patients, but aperiodic exponent and outcome do not sci:sha256:398ad0c4813dba23a5e3270f2aa74722c599a5916eec0eb90a71accc37c3eed1
Its pipeline computed the bipolar band power, line length and spike-like rate features from ds004100.
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesSOZ pairs in 35 HUP SEEG patients showed a small 1–4 Hz clip-to-clip change after level control
The two-clip bipolar feature tables and participants table are copied without change from this package.
- supportsIn four HUP patients, 30-second SOZ AUC windows were usually within 0.05 of the six-minute estimate
In other data (ds005624, 12 x 30-s windows, 4 patients), averaging windows also changed the AUC of high-frequency power and line length by less than 0.01 (mean D -0.002 and -0.001).