sciscape Publications
← All publications

Reciprocal CCEP N1 latency coupling was not significant after distance and contact effects were removed in 8 SEEG patients

We tested whether contact-level cortico-cortical evoked potential (CCEP) N1 latency in one direction predicts latency in the reverse direction after accounting for distance and sender- and receiver-contact effects. We analyzed expert-checked N1 peaks from OpenNeuro ds005448 v1.0.0 (STReEF): 8 SEEG patients as the primary cohort and 5 ECoG patients in secondary analyses. For each patient, we estimated directed contact-level latency, fitted ordinary least squares models with sender and receiver effects, log distance, squared log distance, and same-shaft status, and measured Spearman correlation between residual latencies for reciprocal dyads. Across 1,593 SEEG dyads, residual coupling was not significant (mean rho = 0.086; positive in 5/8 patients; exact sign-flip p = 0.14; Holm-adjusted p = 0.14). Raw coupling was 0.180 (7/8 positive; p = 0.023; Holm p = 0.070), and fell to 0.139 after distance adjustment. The latency-distance slope was positive in all 8 SEEG patients (0.52 ms/mm; Holm p = 0.031). Across all 13 patients, residual coupling was 0.107 (10/13 positive; p = 0.0078), driven mostly by ECoG; residual coupling was not shown at the 13 mm minimum-distance sensitivity threshold. These results do not show a significant dyad-specific shared path in SEEG. A small residual effect remains possible because the primary cohort has 8 patients. Limitations include a single center, Euclidean rather than fiber distance, mapping bipolar stimulation pairs to contacts, and non-independent dyads within patients.

cortico-cortical evoked potentials · CCEP · N1 latency · SEEG · ECoG · reciprocal connectivity · intracranial EEG · OpenNeuro

Admitted 3 citing publications

References

4
  1. supportsExpert-checked CCEP N1 latency increased with Euclidean distance in all 8 SEEG patients; an age effect was not shown in 13 patients sci:sha256:0edf197a069dcfbb5a90b3c78e72e3dc4d41718b6848db0e4b22812aef830255

    H4 shows the same positive N1 latency-distance slope in 8/8 SEEG patients with a different contact-level method.

  2. usesA forward CCEP N1 response predicted higher reverse-response odds in five Mayo SEEG patients, mainly at short distances sci:sha256:09edc4a6bb6ffd3eaa35410552132f855ce5c5c91602a991dcf9787844df5b22

    That work showed reciprocal N1 presence in ds004774. This work uses the same dyad design to test reciprocal N1 latency in ds005448.

  3. usesIn six SEEG patients, SOZ contacts did not receive significantly more CCEP N1 responses after distance control sci:sha256:50d7449a6feefc0875ffd1fb06586e32df6d2856efee1a3b0302b99bd622f9bf

    The ds005448 input files and SHA-256 values come from this package.

  4. usesdoi:10.18112/openneuro.ds005448.v1.0.0

    This study analyzes expert-checked N1 peaks and electrode and channel metadata from OpenNeuro ds005448 v1.0.0 (STReEF).

Cited by

3 publications

Public catalog entries on Sciscape.