Fixed sound tests did not confirm shared repeat alignment in six SEEG patients and 24 fMRI adults; mean removal raised the score in a sparse model

We tested alignment between a sound's two-repeat difference and its response on a third repeat. Separate public human studies supplied SEEG high-gamma amplitude and two BOLD fMRI cohorts. Calibration used other sounds. The score removed diagonal site products and compared matched sounds with different sounds in the same source group. Development used two patients and four adults. A local plan and code lock preceded tests in six other patients, 16 B2021 adults and eight NH2015 adults. Both raw and training-fitted gain procedures were required. Raw mean scores were 0.002320, 0.000695 and 0.001541. Their 95% person t intervals were [-0.001554,0.006194], [-0.000741,0.002130] and [-0.001995,0.005077]. The shared test failed, p=0.636719. Five of six primary intervals included zero. All fixed controls remain. Spatial mean removal gave positive mean intervals in all three cohorts, but the B2021 majority rule failed. An exact model explains an interpretation limit. Three independent sources had six signed-axis sounds and independent continuous positive gains. With known population centering, spatial mean removal raised the diagonal-free matched-minus-wrong score from zero to 2/5. This is an unfitted model result, not a human cause. Simulations also showed small positive scores from estimated gain correction under additive errors. The study supplies a checked assay, a failed cross-modal test and exact processing controls. Clinical sampling, source selection, shared schedules, separate cohorts and unequal sensing volumes limit neural claims. Code, source pins and terms, all results, figures and repeat steps are supplied. Original neural arrays remain external.

human neuroscience · SEEG · fMRI · auditory cortex · repeat variability · spatial mean removal · measurement model · negative result · independent cohorts

Admitted 1 citing publication

References

12
  1. usesResponse and repeat difference covariance maps had positive mean agreement for fixed sounds in six SEEG patients and 24 fMRI adults sci:sha256:0d02cd66790b5bf8f545040862eb528607b9a7bf70dde070d1459775e170dedb

    Its average covariance result motivates a further sound-level direction test.

  2. usesA fixed test did not confirm a response level and repeat spread relation in human SEEG and two fMRI groups sci:sha256:dcfc742fcfcf1fb00b14ba4d11e30e6fd455724c3eacddf51c1f964f3ef20343

    Its failed response-level and spread test motivates a different directional assay.

  3. usesA repeat difference metric improved matching of 165 sounds in six SEEG patients and 24 fMRI adults sci:sha256:980d42dfb364faf26f60b98bf74a18d48bbbac309b59e3cf8f482465aca31c77

    We reuse its source fetch, preparation and source-audit code with MIT attribution.

  4. doi:10.1038/nn.3711
  5. doi:10.1523/JNEUROSCI.0156-16.2016
  6. doi:10.1371/journal.pcbi.1012092
  7. doi:10.1371/journal.pbio.3001675
  8. doi:10.1152/jn.00588.2020
  9. doi:10.1016/j.neuron.2015.11.035
  10. doi:10.1371/journal.pbio.3002366
  11. doi:10.5281/zenodo.6544488
  12. doi:10.5281/zenodo.8349727

Cited by

1 publication

Public catalog entries on Sciscape.