Same-shaft SEEG N1 responses were not consistent across 8 patients at equal distance (median OR 1.39; 5/8 above 1)
We tested whether stereo-electroencephalography (SEEG) recording contacts on the stimulated electrode shaft show expert-checked early N1 responses more often than contacts on other shafts at equal distance from a stimulated bipolar pair. We analyzed an archived stimulated-pair-by-contact table from OpenNeuro ds005448 (STReEF), covering 8 patients (STREEF06-13) and clinical 1-2 mA single pulses. The primary analysis included gray-matter contacts 10-50 mm from the pair midpoint (10,244 rows; 808 same-shaft rows), stratified by stimulated pair and 5-mm distance bin. The median patient-specific Mantel-Haenszel odds ratio was 1.39 (5 of 8 above 1); the exact sign-flip test gave p = 0.070 one-sided (0.14 two-sided), and the pooled odds ratio was 1.17. Two patients had strong same-shaft excesses (OR 3.21 and 5.94; within-patient permutation p = 0.001 and 0.0005), while three had OR below 1. Sensitivity analyses gave median OR 1.11 for gray plus other tissue (6/8 above 1, p = 0.16) and 1.21 for all tissue (6/8 above 1, p = 0.090). These data show no consistent same-shaft excess across patients at equal distance. They do not exclude a moderate average effect: there were 8 patients and few same-shaft contacts beyond 30 mm. Shaft membership is confounded with anatomy, so any observed effect does not prove conduction along an electrode track. The evidence comes from one center, clinical currents, binary expert labels, and Euclidean distance.
stereo-electroencephalography · SEEG · cortico-cortical evoked potentials · CCEP · N1 response · electrode shaft · distance · Mantel-Haenszel odds ratio · permutation test · OpenNeuro · STReEF
References
2- usesWhite-matter stimulation pairs showed more distance-adjusted N1 responses in five of eight SEEG patients sci:sha256:f7da61230d7412c49e29fa2b54224ba3799dd082dd3a536890abc94af1ee630f
We used its archived stimulated-pair x contact table (results/pairs_contacts.json: expert N1 labels, distances, tissue and same_shaft fields) from ds005448 as the only input.
- usesdoi:10.18112/openneuro.ds005448.v1.0.0
The archived stimulated-pair-by-contact table used for this analysis was derived from the STReEF SEEG data in OpenNeuro ds005448, version 1.0.0. The publication records that source and the importer supplied matching version-specific metadata.
Cited by
3 publicationsPublic catalog entries on Sciscape.
- usesA distance-only CCEP response model did not transfer across two SEEG datasets without refitting
Source of the ds005448 contact-level table with expert N1 labels and distances.
- supportsCCEP responses decreased with distance at five stimulation sites in one SEEG patient, while far-response rates varied
Gives a CCEP distance relation in a different dataset (ds006254, 5 mA) with the same decrease of response with distance.
- usesIn 28 SEEG patients, refitting the intercept on two stimulation sites lowered held-out log loss, but half the gap to a patient model remained
Uses its ds005448 site-by-contact table (sha256 4bfd19d2...).