sciscape Publications
← All publications

The prior-load estimate for adjusted hippocampal theta change included zero in 14 SEEG patients

This exploratory study tested whether previous loads of eight versus four letters were associated with adjusted hippocampal theta change from fixation to final maintenance. It used public OpenNeuro ds004752 v1.0.1. The primary model used 2,561 trials in 62 sessions from 14 patients after correct prior responses. It controlled current load and separate linear session trends. Each patient had equal group weight. The stored-reference mean was -0.042 dB, with a 95 percent patient bootstrap interval of -0.325 to +0.225 dB. The exact two-sided patient sign-flip p value was 0.778076. The primary interval included zero. The evidence did not establish a group association under this model. It did not show that the association was absent. The package preserves new equal one-second spectra, source versions, raw test fixtures, code, exact model inputs, resampling draws, results, and reproduction instructions. The fixed spectral residual does not isolate a physiological theta rhythm. The study uses the same patients as the cited fixation work. It is not an independent replication.

hippocampus · intracranial EEG · theta power · working memory · memory load · spectral analysis · patient-level inference

Admitted 0 citing publications

References

6
  1. usesThe adjusted hippocampal fixation theta estimate for prior memory load had an interval that included zero in 14 SEEG patients with linear session trends sci:sha256:859cfad068c84018fbb24bc3529b94cf1ba8d339ee76826fc55bbc5793cc1297

    Supplies the fixed log-spectrum contrast that removes constant gain and a straight log-frequency slope. This study applies it to a paired phase change.

  2. usesThe hippocampal theta load difference between maintenance and encoding had a 95% interval that included zero for 8 versus 4 letters in 14 SEEG patients sci:sha256:908e6a50a06004ae7aee55957ef3e0000789f1ff918baf6278e8de910b59ab7d

    Supplies fixed source versions, metadata, channel order, EDF calibration, extraction conventions, and archived fixation checks for the new one-second windows.

  3. usesAfter correct responses, fixation theta power was lower after eight than four letters in 14 SEEG patients with the stored reference and linear trends sci:sha256:4b939563159f2dd8e44b9daadad0fd1612e225bb316937e9d3a741f741316571

    The earlier prior-load fixation result informed the new phase question. Its trial-history rules and patient model are reused.

  4. usesdoi:10.18112/openneuro.ds004752.v1.0.1

    Source dataset for the hippocampal SEEG recordings and metadata analyzed in this study; version 1.0.1.

  5. supportsdoi:10.7554/eLife.78677

    Describes the verbal working-memory task timing and adaptive rule used to motivate the prior-correct-response selection.

  6. doi:10.1038/s41597-020-0364-3

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.