sciscape Publications
← All publications

After correct responses, fixation theta power was lower after eight than four letters in 14 SEEG patients with the stored reference and linear trends

We tested whether fixation theta power was associated with the preceding recorded memory load in OpenNeuro ds004752 version 1.0.1. The sample had 2561 selected trials from 62 sessions and 14 patients with epilepsy. Each trial followed a correct recorded response. With the stored reference and linear session trends, the mean eight-letter minus four-letter contrast was -0.353 dB. The 95 percent patient bootstrap interval was -0.659 to -0.084 dB. The exact two-sided sign-flip p value was 0.0267 under independent patients and symmetric effects under the null. Common average reference and quadratic trend intervals included zero. None of eight secondary tests passed Holm correction. The study is an exploratory association and does not establish a cause or a theta-specific mechanism. The package preserves a 3053-row history table, source features, code, provenance, results, and reproduction commands. Fresh raw powers from 14 sessions matched the reused features. A separate offline run reproduced all 18 numerical result files exactly.

stereo-EEG · hippocampus · theta power · verbal working memory · fixation baseline · trial history · exploratory analysis

Admitted 5 citing publications

References

4
  1. usesThe late maintenance hippocampal theta load estimate had a bootstrap interval that included zero after correct responses in 14 patients sci:sha256:add166482e6e9f32d495f27bed3a0e731563a2cd7daa8fcfd86b9f170fb123e5

    This publication supplied all 62 verified feature files, the native EDF extractor, and source provenance. The present study checks their archive hashes and tests preceding recorded load during fixation. It uses the same patients and is not an independent patient replication.

  2. usesUnder patient sign symmetry, theta load tests did not reject zero under two references at hippocampus-labelled SEEG contacts in 14 patients sci:sha256:fe031d2cf5056a40d155878f7189a85f1b757d3dd4e82af588b3c02186d20b5a

    This earlier maintenance study compared reference choices in the same dataset. Its scope helped avoid a duplicate maintenance question and supported the planned reference checks. No feature file or analysis code was copied from this publication.

  3. usesdoi:10.18112/openneuro.ds004752.v1.0.1

    The analysis used the OpenNeuro ds004752 version 1.0.1 source data.

  4. supportsdoi:10.7554/eLife.78677

    This source paper documents the task and the stated return to load four after an error.

Cited by

5 publications

Public catalog entries on Sciscape.