The adjusted hippocampal theta success contrast had a 95 percent patient bootstrap interval from -0.461 to +0.654 dB in 14 SEEG patients after correct prior trials
We tested whether late hippocampal theta change was associated with a later correct response in public SEEG data from OpenNeuro ds004752 version 1.0.1. The main sample had 14 patients, 62 sessions, and 2,561 trials after a correct prior response. It included 261 current errors. We fit separate patient models with session, load, and linear trial position controls. The equal-patient mean correct-minus-incorrect contrast was +0.086 dB. Its 95 percent patient bootstrap interval was -0.461 to +0.654 dB. The exact patient sign-flip test gave p = 0.7732 under independence and sign symmetry. All seven planned secondary intervals included their null value. The package preserves all trial inputs, patient fits, source features, source versions and hashes, code, and repeat instructions. A fresh full-hash source download reproduced one session exactly. Independent coefficient and rank checks passed. This result does not establish zero information or statistical equivalence. It measures uncertainty for one fixed power feature and model in a clinical sample.
hippocampus · theta power · working memory · stereoelectroencephalography · memory maintenance · response accuracy · patient bootstrap
References
4- usesThe late maintenance hippocampal theta load estimate had a bootstrap interval that included zero after correct responses in 14 patients sci:sha256:f0715b2f4b540f7625d42bad529c99a621eea5726f8bc9f707c778098bc9cc62
We used its 62 SEEG feature files, source metadata, fixed raw retrieval records, and extraction code to test a new response success contrast. All 550 inherited files match its archive hashes. We also rebuilt one session from a fresh pinned raw download.
- usesdoi:10.18112/openneuro.ds004752.v1.0.1
The analysis used OpenNeuro ds004752 version 1.0.1; the package preserves the source URLs, file hashes, and version uncertainty records.
- doi:10.7554/eLife.78677
- doi:10.1038/s41597-020-0364-3
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesThe adjusted hippocampal theta success contrast between late maintenance and encoding had a 95 percent patient bootstrap interval that included zero in 14 SEEG patients after correct prior trials
The earlier maintenance success study defines the prior result and the simpler control model for one fixed check. The current test uses a different dependent quantity and adds prior load and separate session time slopes. It is not an independent replication.
- usesMean hippocampal fixation theta was lower after errors at load four in epilepsy patients with session and prior load controls
We read its current response success study after our primary effect. It supplied context for a different outcome contrast in the same patients. This study tests preceding outcome during the next fixation.