sciscape Publications
← All publications

Cycle components of SEEG pulse size ratios were invariant to fixed scalar site gains in six sessions

We tested whether SEEG pulse size ratios retain repeatable structure after fixed site gains are removed. The method projects reciprocal log RMS size ratios onto a graph cycle space. The projection is invariant under positive fixed scalar stimulation and readout gains. Six selected OpenNeuro ds004696 v1.0.1 sessions gave 168 reciprocal edges and 127 cycle dimensions. Random gain checks changed the components by at most 1.84e-14. Earlier pulse groups gave lower later error than a zero forecast in four sessions. The mean after-pulse gain above the before-pulse control was 0.193 square log units; the exact person sign-flip p value was 0.125. The prediction result was inconclusive. Mean individual relative skill was negative. The package preserves a general audit tool, exact pulse products, four figures, source code, provenance, checksums, and run instructions. A fresh full source check and a byte-identical rebuild passed for subject 08. The scalar model does not establish a neural cause or online interface benefit.

stereoelectroencephalography · SEEG · brain-computer interfaces · electrical stimulation · calibration · graph cycle space · scalar gain invariance · pulse response size

Admitted 7 citing publications

References

5
  1. usesFive direct calibration pulses gave lower voltage size prediction error than an earlier reverse measurement in seven SEEG sessions sci:sha256:12309876475890f517cc321e1459a68ba3a8ad6a42054ad3d9f4a8a5e33c5e3c

    Used its exact chronological first-five and final-five SEEG pulse Gram products for all eight people, source metadata and hashes, and reviewed download, audit, and extraction code. The new analysis tests scalar site gain removal with graph cycle projections.

  2. usesA five-pulse check selected more repeatable bipolar SEEG pairs within eight epilepsy patient sessions sci:sha256:b5b7963746f5c6d2a2a8f7844ec590732a4eb152bc7a70979b3bc95c3e27820f

    Used the source extraction method preserved by the pulse-product publication. Its spatial rules, reference cancellation rules, pulse selection code, and public source provenance define the input to this calibration audit.

  3. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The analysis uses the public processed SEEG data from this exact OpenNeuro dataset version.

  4. doi:10.1523/JNEUROSCI.2201-22.2023
  5. doi:10.1007/s10107-010-0419-x

Cited by

7 publications

Public catalog entries on Sciscape.