Exact Gamma product predictions reduced later one-minute MNI HFO count loss in 18 SEEG records under a fixed fit rule
We tested exact count probabilities for released MNI HFO marks in 18 public SEEG records from OpenNeuro ds005398. The comparison used a fixed fit rule and a negative binomial approximation with the same mean and variance. Models fitted the first 30 minutes and scored 38,550 channel bins in the next 30 minutes. Equal-patient mean loss fell from 1.177612 to 1.169308 nats per channel-minute. The mean gain was 0.008303 nats. The 95% patient bootstrap interval was 0.000915 to 0.022025. This interval assumes independent, exchangeable patients for population use. Fifteen patients had positive gains. UCLA49 supplied 80.43% of the summed gain. The mean gain without that patient was 0.001721. All seven fixed secondary checks retained positive mean gains. The package preserves source inputs, exact probability code, a moment proof, every prediction, numerical checks, and repeat instructions. All 94 fresh public source checks passed. All 22,507 distinct probabilities passed a second integral check. A full offline repeat matched 54 generated files byte for byte. This is a local test in a reused cohort. It does not establish event validity or clinical benefit.
Gamma product · negative binomial · count prediction · high frequency oscillations · stereoelectroencephalography · marginal probability · held-out prediction · patient bootstrap
References
5- usesAn excess variance rule lowered prediction loss for HFO counts in 135 excluded SEEG sleep records from seven patients under record exchangeability sci:sha256:9febe1f024cef70f3934a38192744e15a5127f925e8083529c6df7cbd708b9f1
This work supplied the earlier excess variance rule used by our immediate source. We retained its count prior constant, patient variance formula, and cap while changing the marginal probability calculation.
- usesAn update from unfiltered STE marks at strength 0.5 increased mean MNI map error in later 30-minute samples from 18 SEEG records sci:sha256:e301b57e3f3c1121c28c87ff1ff448653851a58474dc972f0a5fc83f41038cac
This work supplied the upstream pinned public source archive and source score convention. We obtained them through the cited count study and checked all 94 public inputs again.
- usesA one second history term improved mean time scores for 50 ms joined MNI marks in the second half hour of 18 SEEG sleep records under a 60 second rate control sci:sha256:90c8f2004f242b939c1289e7f0f687855acab100251918b548af1af8010709dc
This work supplied context on count history in the reused cohort. It did not supply analysis inputs or model code for the exact product test.
- usesA fixed variance rule reduced prediction loss for later one-minute counts of unfiltered MNI HFO marks in 18 public SEEG sleep records sci:sha256:72f21f20f6b9dcfc92cc17c59090ef9f0dd07930e1b99d92c42ef8619684350a
This work supplied the pinned ds005398 inputs, source checks, extraction and retrieval code, and fixed fit rule. We reproduced its moment approximation and tested exact product probabilities with the same mean and variance.
- usesdoi:10.18112/openneuro.ds005398.v1.1.3
This version-pinned OpenNeuro dataset supplied the public SEEG detector marks and metadata analyzed in this study.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.