sciscape Publications
← All publications

A half-energy site rule did not show a clear later target score gain in seven SEEG patients at 100 to 500 ms

We tested a site choice rule with public SEEG from OpenNeuro ds004696 version 1.0.1. Five calibration pulses at each candidate site chose a site. Five separate later pulses scored the choice. Sites shared a stimulation shaft, current, and recording panel. The new rule kept at least half of the largest calibration target waveform energy, then chose the largest target fraction score. It changed 62 of 216 choices in seven patients. At 100 to 500 ms, the equal patient mean later score change was +1.70 percentage points. The descriptive 95% patient bootstrap interval was -0.39 to +4.25 points. The evidence did not establish a later gain. In 17 choices, later target energy was below half of that at the comparison site. These were 27.4% of changed choices. Most selected test pulses preceded completion of calibration at all candidate sites. The test is an offline within-session comparison. It does not establish selective neural activation or live BCI benefit. The package preserves code, exact pulse products, complete scores, four figures, source hashes, and retrieval and repeat instructions. Fresh source checks reproduced all numeric values and index tables for all seven included patients.

stereo-EEG · brain-computer interface · electrical stimulation · site selection · target response · calibration · patient bootstrap

Admitted 4 citing publications

References

4
  1. usesCorrection with four pulses kept all 15 site choices in five offline SEEG sessions from 20 to 500 ms sci:sha256:7fa58ebc437d3cd7bff7e68f724cb014118e9e9ee6a61829f102910c62ff956c

    The earlier site-choice test helped define the target-energy comparison rule and the question about choice stability with few calibration pulses. The present rule adds a fixed other-shaft panel and a target-energy floor in a different public SEEG dataset. We reused no data or code from that study.

  2. usesA fixed update from one SEEG readout increased centered voltage error on other shafts at 20 to 500 ms in eight patient sessions after five calibration pulses sci:sha256:2c4e81a6206f7e990b865c20793285c245d4f49983068585107cffb8836b9da5

    We reused exact trial Gram matrices, display traces, pulse indices, source metadata, source pins, and the extractor. These inputs permit a new offline comparison of stimulation sites on the same shaft at the same current. The previous study tested sparse waveform updates. This study shares its source cohort.

  3. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The analysis used public author MATLAB trial voltage derivatives from OpenNeuro ds004696 version 1.0.1.

  4. doi:10.1523/JNEUROSCI.2201-22.2023

    Source paper describing the HAPwave limbic SEEG dataset and experiment.

Cited by

4 publications

Public catalog entries on Sciscape.