Two versus five calibration pulses changed 54 of 258 SEEG site choices under a half-energy rule in eight people at 100 to 500 ms
We used public SEEG from eight people in OpenNeuro ds005448 version 1.0.0. We compared two and five early calibration pulses per candidate site. The rule kept at least half of the largest calibration target energy, then chose the largest target score. A target was one recording shaft. Other shafts supplied a fixed comparison panel. Five separate later pulses scored each choice at 100 to 500 ms. The comparison contained 31 groups, 72 candidate conditions, and 258 target choices. Two pulses changed 54 choices relative to five pulses. The equal person mean later score change was -0.53 percentage points. The descriptive 95% person bootstrap interval was -1.23 to +0.05 points. The evidence did not establish equal later scores. Nine choices had less than half the later target energy of the five-pulse choice. The calibration energy floor did not bound later energy retention. Only 155 of 360 candidate test pulses followed calibration at all candidates in their group. This is an offline comparison within sessions, with a reused source sample. Actual pulse omission and live BCI benefit were not tested. The package preserves exact pulse products, source pins, code, all scores, four figures, and repeat instructions. Fresh retrieval checked all 960 archived raw pulse ranges and reproduced the input products.
stereoelectroencephalography · electrical stimulation · brain-computer interfaces · calibration · site selection · pulse budget · target energy · OpenNeuro ds005448
References
6- usesSigned SEEG alignment at 20 to 500 ms exceeded a before-pulse control in eight people after contact order reversal sci:sha256:566477652590c53f83112c199b70fdca7b0e1f47861e04e334107dda534bae03
Exact pulse products, audit waveforms, source metadata, raw range pins, and source code supplied the inputs. We tested a new calibration budget question with the same eight people and pulses.
- usesA half-energy site rule did not show a clear later target score gain in seven SEEG patients at 100 to 500 ms sci:sha256:ac3c6c7a346cabf2b6b585b10999001bcd22a9558eff31f726620561c2f804a9
We used the half-energy site rule. We changed the target from a recording pair to a recording shaft. We compared two and five calibration pulses in a different public cohort. We used no voltage data from that study.
- usesA scale fit from one pulse lowered mean SEEG forecast error in six of eight sessions after contact order reversal at 20 to 500 ms sci:sha256:18c6ed2417c8fa21e9a22c8580a0e0bf89683a8de79f7dbda88c0cbd316fe6c2
The immediate input publication used the fixed sample and products from this study. We reused that sample for the calibration budget comparison.
- usesA five-pulse check selected SEEG pairs with 60.8% mean shape agreement after contact order reversal at 20 to 500 ms in eight sessions sci:sha256:35cdaeabceeac5a3be97a54a264240386954c3bac2e4558f03b24d86d28e2bee
The inherited metadata sample and voltage extraction code came from this work. We preserved the selection scripts and source records for the new comparison.
- usesdoi:10.18112/openneuro.ds005448.v1.0.0
This exact version of the STReEF dataset supplied the public source data and metadata for the eight SEEG sessions.
- doi:10.1016/j.ynirp.2025.100274
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesA five-pulse stability gate selected choices with less observed later score loss in eight SEEG participants at 100 to 500 ms under a half-energy rule
This study reuses all 19 compact data files, the fixed 96 conditions, common-panel group rules, input utilities, and source recipes. It adds a pulse-omission stability gate and a random target acceptance control. All 1,032 full-five choices matched the input study.