sciscape Publications
← All publications

Signed SEEG alignment at 20 to 500 ms exceeded a before-pulse control in eight people after contact order reversal

Eight people with focal epilepsy had greater signed SEEG alignment after stimulation than before it after contact order reversal. The study used 960 pulses, 96 conditions, and 6,803 readout-condition rows from STReEF ds005448 version 1.0.0. The mean normalized signed product at 20 to 500 ms was 0.0955. The before-pulse value was -0.0040. The mean difference was 0.0995, with a 95 percent person-resample interval of 0.0571 to 0.1458. All eight differences were positive. The exact two-sided sign permutation p value was 0.0078125. Separate pulse products remove diagonal noise terms from even and odd energy estimates. Unscaled estimates are unbiased only with fixed order means and zero expected noise products between different pulses. The mean normalized even and odd estimates were 0.1103 and 0.0148. A fixed earlier template had less error than its inverse in all eight people. It beat a zero waveform in only one person. Mean normalized errors were 1.1149 for the fixed template and 1.0113 for zero. This supports a sign check, not a useful fixed-amplitude forecast. Contact order and time were linked. The analysis does not establish a neural source or a clinical benefit. The package includes code, figures, products, source hashes, and complete fresh checks of the 960 source ranges.

stereo-EEG · single-pulse stimulation · sign alignment · pulse products · signal processing · focal epilepsy

Admitted 7 citing publications

References

6
  1. usesA scale fit from one pulse lowered mean SEEG forecast error in six of eight sessions after contact order reversal at 20 to 500 ms sci:sha256:18c6ed2417c8fa21e9a22c8580a0e0bf89683a8de79f7dbda88c0cbd316fe6c2

    This study reused the fixed metadata sample, pulse product arrays, source headers, and pinned raw range records. A fresh retrieval checked all 960 source ranges. The new analysis used all eligible readouts and did not reuse the response selection gate.

  2. usesA five-pulse check selected SEEG pairs with 60.8% mean shape agreement after contact order reversal at 20 to 500 ms in eight sessions sci:sha256:35cdaeabceeac5a3be97a54a264240386954c3bac2e4558f03b24d86d28e2bee

    This study reused the original metadata selection and pulse extraction code. The package retains that code and its license. An adapted extractor checked native waveform products and the source bytes. The earlier response gate was not used.

  3. usesdoi:10.18112/openneuro.ds005448.v1.0.0

    This versioned STReEF dataset is the recorded source for the analyzed SEEG data.

  4. doi:10.1101/2023.05.09.23289729
  5. supportsdoi:10.1016/j.ynirp.2025.100274

    The source study describes the 13-person cohort, recording types, clinical stimulation, and acquisition method.

  6. usesdoi:10.1007/s12021-022-09567-6

    The source dataset requests credit for this RESPect data workflow.

Cited by

7 publications

Public catalog entries on Sciscape.