Baseline subtraction reduced mean relative SEEG disagreement across all disjoint five pulse splits for selected contacts in five patients
We tested whether scalar baseline subtraction reduced disagreement between separate SEEG pulse means. We used OpenNeuro ds004457 version 1.0.2. The fixed sample had 1081 links, 40 selected contacts, and five patients. Each site had ten pulses. Each comparison used two separate groups of five pulses. The baseline was -120 to -20 ms. The target was 60 to 160 ms. We averaged loss across all 252 oriented splits. We then averaged relative reductions across links and patients. The mean reduction was 46.98%. The descriptive 95% patient bootstrap interval was 30.31% to 66.26%. The exact two-sided patient sign flip p value was 0.0625. All five patient means were positive. The before-stimulation control gave a 48.59% reduction. Scalar subtraction changed mean voltage level and left time-centered shape unchanged. The chronological check depended on how link errors were combined. Lower disagreement does not establish lower neural response error. Every saved voltage bin matched the raw data. The package preserves code, pulse data, source hashes, results, checks, and instructions.
stereoelectroencephalography · SEEG · baseline subtraction · electrical stimulation · pulse averaging · voltage disagreement · signal processing · intracranial EEG
References
7- usesLocal amplitude increased SEEG prediction error in fixed ridge models with ten pulses per site in five patients sci:sha256:90ca56b8a16b4c5aa8d53cd988ab288b768c0a93af72bec8cfbba1edff975ee6
Its baseline amplitude prediction test informed the choice of a separate scalar voltage correction endpoint.
- usesStudent t intervals covered 93.48% of bins but 45.93% of full SEEG waveforms in five patients sci:sha256:491d314f93efbf6e2bd0bee36cf04c368664632fef1d443d036e37a52047dbc6
Its repeated pulse coverage results informed the stated limits on prediction from the fixed pulse pool.
- usesFour shared pulses increased correlation between five pulse SEEG averages in five patients sci:sha256:b32094dc7392cb00836046de174e97c74b5e22bff748e10cb681317ecbf47b6d
This study supplied the locked pulse data, contact selection rule, extraction code, and raw source recipe.
- usesBaseline subtraction retained a pulse-count term in a fixed test of 1,081 SEEG links from five patients sci:sha256:c54ff982cb3901bbf39f5043ffe766192721b249eaad32d28a83cb826ecc0378
This study was read after our results. Its energy subtraction test clarified the difference from scalar voltage subtraction.
- usesdoi:10.18112/openneuro.ds004457.v1.0.2
Analyzed pulse data and source metadata came from OpenNeuro ds004457 version 1.0.2.
- doi:10.1523/JNEUROSCI.1325-22.2023
- doi:10.1111/psyp.13451
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.