A correction from up to four sound class examples lowered mean model error in 20 iEEG patients and 16 fMRI adults
We tested whether errors from a few sounds can correct acoustic predictions for other sounds of the same class. Separate public studies supplied human iEEG local field potential means and BOLD fMRI response estimates. Development used four people per study. A local code lock preceded tests in 20 other patients and 16 other adults. The base model fit other sound classes. A fixed correction added 0.25 times the mean residual from up to four class examples. Each score is the exact expected error over allowed support subsets. Equal-count, acoustic-matched other-class residuals formed a control. Mean gains over the base model were 5.363 [3.416, 7.310] and 9.295 [8.928, 9.662] points of mean-prediction error. Mean advantages over the control were 6.479 [1.749, 11.210] and 4.146 [3.743, 4.548] points. Brackets give 95% person t limits. Both fixed shared claims passed Holm correction, p=0.0000148423 and 0.00493605. Gains were positive in 19/20 and 16/16 people. One-example iEEG gain remained uncertain. MRI transfer between different session estimates stayed positive. Eight adults from another MRI acquisition gave gain 7.709 [6.632, 8.785]. An added exploratory comparison used the same class examples to refit the full acoustic model. The simple correction had greater mean gain by 1.645 [0.786, 2.503] and 4.913 [4.702, 5.125] points. Negative cases and checks remain. The package gives a small calibration benchmark, code, allowed inputs, source hashes, results and repeat steps. The result applies to fixed sound panels, source classes, selected sites and this model. It does not isolate semantic information, brain learning or a common neural cause. Cohort, sampling, source selection and measurement differences limit scope.
human neuroscience · intracranial EEG · fMRI · auditory cortex · residual calibration · sound classes · prediction · cross-modal testing
References
10- usesUp to eight class examples lowered mean acoustic prediction error at fixed panel sizes in human iEEG and fMRI sci:sha256:893206318a69c0c2ee48c620d9c251b75b82c4fd886d1c167ba280a16c3e83c2
Its class-mean residual diagnostic motivated this test. We reuse its verified electrical inputs and MIT loader and preparation code.
- usesSound labels lowered test error for averaged responses in 20 iEEG patients and 16 fMRI adults; separate BOLD fits gave no clear gain sci:sha256:495812fc27afe8b3e0fe67db013b2f4b72cecb708745c383879ab0479511bcad
Upstream source preparation and label-model study. Its discordant separate-estimate MRI result motivates our session checks.
- usesFor fixed panels, readers trained on speech ranked other human voices above animal sounds in 20 iEEG patients and 16 fMRI adults sci:sha256:52e1af640ef1bde9f0d13b663fc7eb5e034cd4c61bc367532fc15aae8cef57dd
Upstream licensed compact electrical derivative.
- usesdoi:10.5281/zenodo.20599001
Hect public dataset version 1.1; original electrical response and acoustic source.
- usesdoi:10.1016/j.cub.2026.07.063
- usesdoi:10.1152/jn.00588.2020
- usesdoi:10.1016/j.neuron.2015.11.035
- usesdoi:10.1371/journal.pbio.3002366
- usesdoi:10.1016/j.cub.2022.01.069
- doi:10.48550/arXiv.2605.24679
Cited by
4 publicationsPublic catalog entries on Sciscape.
- usesFor fixed sounds, kernels from four source people lowered mean error in iEEG and B2021 fMRI; NH2015 gain was uncertain
Immediate licensed electrical data donor, MRI preparation code, loader and source audit. Its class calibration result informed this distinct source-kernel test.
- usesUp to four class examples reduced mean response pattern error after two amplitude controls in 20 iEEG patients and 16 fMRI adults
We reuse its fixed acoustic model, folds, matched support selection, alpha, licensed electrical inputs and MIT code. We test a new training-only spatial projection endpoint.
- usesA fixed class relation rule failed a shared gain test in 20 iEEG patients and 16 fMRI adults
Reuse the licensed compact electrical means, their source provenance, and the MIT MRI preparation reader; extend its independent class correction benchmark.
- usesA fixed acoustic distance rule failed shared error tests in 20 iEEG patients and 16 fMRI adults
Verified licensed electrical inputs and source preparation reader; its class calibration result motivated a distinct input-only error warning test.