Sound labels lowered test error for averaged responses in 20 iEEG patients and 16 fMRI adults; separate BOLD fits gave no clear gain
We tested whether source sound labels improve prediction of responses to sounds kept out of fitting. Separate public human studies supplied signed iEEG repeat means and BOLD fMRI. Four people per study supplied development. Fixed tests used 20 other patients and 16 other adults. The baseline combined linear and nonlinear acoustic kernels. A category kernel and an acoustic clustering control used fixed weights and equal group counts. Mean category gains were 2.434 [0.886, 3.981] and 3.342 [2.168, 4.516] percentage points against intercept error. Brackets give 95% person Student limits. Advantages over acoustic clusters were 2.418 [0.553, 4.283] and 7.577 [6.590, 8.564] points. Both shared rules passed Holm correction, p=0.011818 and 0.020695. However, all three separately fitted BOLD estimates had gain intervals across zero, although all beat acoustic clusters. An exact fixed-prediction identity and a later audit separate test averaging from refitting. A further eight-person fMRI acquisition check had mean gain 1.311 points; its common-test-sound range crossed zero. An acoustic-only construction gave both gains without a separate category information channel. Thus, the finding concerns these processed mean responses and prediction rules. It does not establish information independent of all acoustics or a common neural cause. Cohort, label, sampling, filter and source-selection differences limit scope. The package gives licensed electrical means, source pins and terms, code, all results, figures, audits and repeat instructions. Original MRI arrays remain external.
human auditory cortex · intracranial EEG · fMRI · sound categories · acoustic models · kernel regression · repeat averaging · prediction error
References
8- usesA fixed test did not confirm shared voice label gains in 20 iEEG patients and 20 fMRI adults with linear acoustic models sci:sha256:ae42aba7a4f87b32ba1605d8f9711109760fd08a14aec6db9b7787abf51a0df2
We build on its binary-label prediction question and adapt its MIT HTTP range reader. Our full-category and acoustic-cluster tests differ.
- usesFor fixed panels, readers trained on speech ranked other human voices above animal sounds in 20 iEEG patients and 16 fMRI adults sci:sha256:52e1af640ef1bde9f0d13b663fc7eb5e034cd4c61bc367532fc15aae8cef57dd
We reuse its CC BY 4.0 compact electrical means and labels, with attribution and source records.
- usesdoi:10.1016/j.cub.2026.07.063
- usesdoi:10.5281/zenodo.20599001
- usesdoi:10.1016/j.neuron.2015.11.035
- usesdoi:10.1152/jn.00588.2020
- usesdoi:10.1016/j.cub.2022.01.069
- usesdoi:10.1371/journal.pbio.3002366
Cited by
6 publicationsPublic catalog entries on Sciscape.
- usesSound labels lowered error for omitted acoustic clusters in 18 iEEG patients and two fMRI groups
Prior nonlinear acoustic-plus-class prediction design and its limits; the present study holds out complete acoustic clusters.
- Fixed maps from eight sites gave higher prediction gains within a repeat in six SEEG patients and two fMRI studies
Prior warning that an averaged-response benefit can fail in separate BOLD estimates.
- usesFor fixed sounds, kernels from four source people lowered mean error in iEEG and B2021 fMRI; NH2015 gain was uncertain
Upstream source preparation in the electrical derivative chain.
- usesUp to four class examples reduced mean response pattern error after two amplitude controls in 20 iEEG patients and 16 fMRI adults
Upstream loader and native MRI preparation; a source-model selection caution.
- usesUp to eight class examples lowered mean acoustic prediction error at fixed panel sizes in human iEEG and fMRI
Reuses its pinned source preparation and licensed electrical derivative. Tests a new panel replacement. Keeps discordant results as context.
- usesA correction from up to four sound class examples lowered mean model error in 20 iEEG patients and 16 fMRI adults
Upstream source preparation and label-model study. Its discordant separate-estimate MRI result motivates our session checks.