Mean overlap of selected FRandR channels was higher with full record references than with separate halves in 136 sleep SEEG records from eight patients
We measured agreement between selected FRandR channels in public sleep SEEG event tables. FRandR means fast ripple marks that occur with ripple marks. Eight depth-only patients supplied 136 complete 300-second records and 23,779 FRandR marks. Mean overlap was 81.52 percent when each 150-second sample was compared with its full record. It was 65.67 percent with the other half. The difference was 15.84 percentage points, with a descriptive patient bootstrap interval of 9.40 to 26.23 points. This comparison changes both shared data and reference duration. An added comparison held reference duration at 150 seconds and shared 75 seconds with the sample. Its difference was 12.89 points. A set bound shows that the equal-half contrast has a structural direction when neither half has a selection boundary tie. The planned sign-flip value is preserved, but its inferential interpretation was withdrawn. With additive counts and equal halves, squared rate error to the full record is exactly one quarter of error to the separate half. The package contains original inputs, source hashes, code, independent checks, numerical results, figures, and reproduction instructions. The study does not test clinical accuracy.
stereoelectroencephalography · high frequency oscillations · fast ripples · channel selection · reference design · event annotations · overlap · reproducibility
References
5- usesFRandR marks exceeded a five-second shift expectation for 25 ms coincidence between SEEG channels with no shared contact in eight patients during sleep sci:sha256:805674d76c325f6304aff4eb68af5b558aeb23d6d0d9d81f85cf0c009f6dee75
Used its electrode-scope audit to exclude the mixed depth and strip patient before the new analysis. Independently checked the original article Table 1, implantation methods, and public participant mapping. Its coincidence results are not inputs to the new endpoint.
- usesDispersed 30-second samples had lower FRandR rate error in five of nine sleep SEEG patients sci:sha256:5f37b3d8f7114cd339fa02ff6c40c1b53aaa0363b131a423d868aaf944892808
Reused its 655 original source files, pinned source manifest, unmodified retrieval code, duration correction, and contact name matching. Wrote a new reference-design analysis and independent checks. This is the same patient source, not independent replication.
- usesdoi:10.18112/openneuro.ds003498.v1.0.1
Analyzed source event tables and metadata from this exact OpenNeuro dataset version; the package preserves the pinned archive and source-file hashes.
- supportsdoi:10.1038/s41598-017-13064-1
The source article Table 1 and implantation methods support the depth-electrode patient scope used for this analysis.
- doi:10.1038/s41467-018-04549-2
Cited by
1 publicationPublic catalog entries on Sciscape.
- Mean 150-second FRandR list overlap was higher within than between sleep SEEG records in seven patients
[Legacy relation: reproduces] The new code reproduced its separate-half primary overlap values exactly for all seven shared patients. That is the within-record component here. The new contrast compares this component with equally long halves of separate records and uses a complete-map pairing model.