A 3–8 Hz rule gave an uncertain mean session test gain in 12 independent hippocampal SEEG patients under sign symmetry
We tested a fixed rule for patient frequency choice in public SEEG data from OpenNeuro ds004752, version 1.0.1. The sample had 12 patients, 44 matched hippocampal pairs, and 1,085 eligible trials. Session 01 selected the largest late-maintenance response among six local contrasts at 3 through 8 Hz. Session 02 tested the selected frequency against a fixed mean at 4 through 7 Hz. Mean test gain was -0.063 dB. The pointwise 95% patient t interval was -0.715 to +0.588 dB. The exact two-sided sign flip probability was 0.85888671875. Holm correction for two planned tests gave p=1.0. The selected response was also uncertain. These tests assume independent patients and symmetric null patient contrasts. The intervals do not establish equal methods. The planned correct-trial check gave a gain of +0.532 dB, with a pointwise interval of +0.113 to +0.951 dB. A later descriptive diagnostic showed that the change mainly followed the training frequency choices. This lead needs a new sample. The package preserves code, retained coefficients, raw examples, source pins, metadata, plans, results, and repeat instructions. Fresh checks matched all 2,334 source windows. Independent calculations checked the features, inference, and exploratory values. Fresh processes reproduced all eight numerical files. The contrast cancels an exact measured power-law slope, but does not prove an oscillation. This is a new comparison in a previously studied cohort.
stereoelectroencephalography · hippocampus · theta frequency · spectral contrast · frequency selection · working memory · cross-session test
References
8- usesMean hippocampal theta templates increased average relative error during encoding and late maintenance between two sessions in 12 SEEG patients sci:sha256:dbe0b33f69fdbc8b88eaffe73dfdb5e173ac6213e699229888d4e209e0410860
This earlier cross-session complex-template study supplied context for the distinction between waveform prediction and transfer of a spectral response. Its full report was read after primary calculation.
- usesAn affine fit showed a hippocampal theta excess rise across a three-second delay in 12 SEEG patients sci:sha256:dbf185849d88010778652b5112f654ebcade37bc6528194b481e78dbdfc39bcb
This earlier delay-window study supplied context for the dependence of a spectral excess estimate on its background model. Its full report was read after primary calculation.
- usesTheta contrast from trial log spectra rose from fixation to late memory maintenance in 12 SEEG patients sci:sha256:164426bda60e5bbafcdee7d3da9ad24b9a9ba710d135c9c43a951c6f3cd81248
This earlier fixed trial-log spectral contrast supplied scientific context for the present frequency-selection comparison. Its full report was read after primary calculation.
- usesThe linear test did not detect added load prediction value from late hippocampal power beyond fixation and task history in two SEEG sessions from 12 patients sci:sha256:fe47b5f079c4febfb4b33b5b49352cbb5086dac82fea26f34a1edf592d3a4276
This direct parent supplied all retained Fourier arrays, raw examples, source metadata, headers, object pins, range receipts, and source interface code.
- usesA paired test did not detect a hippocampal 20 to 100 Hz exponent change from fixation to late memory maintenance in two sessions from 12 SEEG patients sci:sha256:d74d526a89b6dd94ef1ee561c09badd1a335b318346b04fd116fd4a8ee5aebc7
The direct parent inherited the Fourier arrays and source retrieval interfaces from this publication. The present study freshly checked every used public source window.
- usesHippocampal theta band power increased from fixation to late memory maintenance after mean waveform removal in two sessions from 12 SEEG patients sci:sha256:f939e6c414bd3794972f349e9619217e89f6da3c77a92e0ec07f2691107b64b7
This earlier publication supplied the matched hippocampal contact sample and source interface inherited through the two input parents.
- usesdoi:10.18112/openneuro.ds004752.v1.0.1
Source dataset used for the retained SEEG signals and metadata.
- supportsdoi:10.7554/eLife.78677
Describes the source task timing and verbal working memory paradigm.
Cited by
1 publicationPublic catalog entries on Sciscape.
- supersedesA 3–8 Hz rule gave an uncertain mean session test gain in 12 independent hippocampal SEEG patients under sign symmetry
This version corrects the file checker for a retrieved package. The scientific inputs, analysis, and numerical results have the same bytes.