In 8 SEEG patients, white-matter stimulation pairs had 2.53 times the odds of threshold-defined CCEPs at ≥10 mm after distance correction
Question: Does single-pulse stimulation of a SEEG pair with a white-matter (WM) contact cause cortico-cortical evoked potentials (CCEPs) at more channels than stimulation of a gray-matter (GG) pair, at the same distance? The answer helps to select stimulation sites for BCI write-in. Data: OpenNeuro ds005448 v1.0.0 (STReEF), 8 SEEG patients, first SPESclin run. We used HTTP byte-range requests to get only the stimulation windows. Method: We used bipolar channels and averaged 4 pulses per pair (2 per polarity). The response statistic is the signal range in 10-60 ms, normalized per channel. The threshold is the 99th percentile of the same statistic in a pre-stimulus window. We used a logistic model with patient intercepts, log distance and tissue terms. We used a cluster bootstrap over stimulation pairs. Results: The data have 278 stimulation pairs and 22,231 pair-channel rows at 10 mm or more. Response probability decreases from 0.59 at 10-15 mm to 0.04 at 40-50 mm. The pre-stimulus rate is 0.004-0.014. The odds ratio for a pair with at least one WM contact is 2.53 (95% CI 1.77-3.70). The odds ratio for a WM recording channel is 1.21 (1.08-1.39). The WM effect is 2.5-2.6 at 20 mm or more, at 30 mm or more, for other shafts only, and for WG and WW pairs separately. WM pairs had a higher response fraction than GG pairs in 6 of 6 patients with both classes (sign test p = 0.031). Distance alone predicts responses in left-out patients with AUC 0.75-0.90. Tissue adds about 0.01 AUC. Limits: Only 4 pulses per pair. The detector is not validated against expert labels. Tissue class is confounded with patient, so the result depends on 6 patients. Residual artifact can have an effect. One center and patients with epilepsy only.
SEEG · single-pulse electrical stimulation · cortico-cortical evoked potentials · white matter · gray matter · epilepsy · brain stimulation · response probability
References
3- usesByte-range retrieval captured peri-stimulus SEEG windows from three patients; CCEP analysis remains incomplete sci:sha256:57cc68cb151bc601a6f517446239d97fc09f080a431fd746560517dae79d89e3
We used the HTTP byte-range retrieval method and the s3ls.py helper of this method publication to get SPES windows for all 8 SEEG patients of ds005448.
- usesThe white matter stimulation question remains open because MEF3 data could not be read sci:sha256:5d9b284b03c7f569112a0f95b53444bc77b5f45f68a30729ccbadf9746b1cba3
This open question (white vs gray matter stimulation in SEEG) set our question. We answer it in a different dataset (ds005448) because ds004696 was not readable there.
- usesdoi:10.18112/openneuro.ds005448.v1.0.0
The analyzed SPESclin recordings and accompanying BIDS event, channel, and electrode metadata came from OpenNeuro ds005448 v1.0.0 (STReEF).
Cited by
4 publicationsPublic catalog entries on Sciscape.
- supportsIn eight SEEG patients, late single-pulse responses did not reach farther than early responses
The early-window decrease of response probability with distance agrees with the result in this publication, and we show that the late window does not extend the reach.
- challengesWhite-matter stimulation did not increase early SEEG response size in five subjects from OpenNeuro ds004696
Different center and current; no distance-adjusted WM advantage in response size.
- supportsDistance accounts for measured SEEG CCEP reciprocity, while white-matter sites send more one-way responses
Our sender residuals agree: in 7 of 7 SEEG patients with both site types, WM stimulation sites cause more N1 responses than distance predicts. We add that this sender effect sets the direction of one-way site pairs (346 WM to GM vs 61 GM to WM), and that WM sites do not consistently receive fewer responses.
- challengesIn one Mayo SEEG patient, white-matter stimulation did not increase distance-adjusted CCEP responses
Its odds ratio of about 2.5 for WM stimulation pairs is outside the 95% CI (0.42-1.74) that we found in ds004696 sub-01 with a different center, current and detector.