The HFO timing AUC change interval included zero within shafts in the first hour of 17 SEEG records under independent, exchangeable patient sampling

We tested whether short HFO timing adds seizure onset zone (SOZ) rank information beyond count and contact position. HFO means high-frequency oscillation. We used released marks from public OpenNeuro ds005398 version 1.1.3. The first hour supplied 474 same-shaft channel pairs in 17 SEEG patients. SEEG means stereoelectroencephalography. We joined detector fragments at 50 ms. We compared 0.1 to 0.5 second onset gaps with a reference that fixes counts in each ten second bin. Each test patient was excluded from both rank-model fits. Mean patient AUC changed from 0.776513 to 0.769064, a change of -0.007449. Its 95% fully refitted patient bootstrap interval was [-0.042149,+0.029891], under independent, exchangeable patient sampling. The fixed feature gave no clear gain. This does not prove equal performance. The timing feature was unavailable on 916 of 1,285 eligible channels. All seven planned check intervals included zero. Independent calculations passed. A full repeat matched all 59 calculation files. The package preserves source bytes, code, versions, results, fits, draws, and repeat instructions. This reused clinical sample does not establish neural event truth or clinical benefit.

high-frequency oscillations · stereoelectroencephalography · seizure onset zone · event timing · same-shaft ranking · patient bootstrap · OpenNeuro

Admitted 2 citing publications

References

6
  1. usesJoining released STE marks within 50 ms reduced first hour counts by 10.3% in 18 SEEG sleep records sci:sha256:b82f10c39a98d9dd89862ddb4b48266895b4f5a50f06fee0d0e478eb897c5cd7

    Its 50 ms interval joining rule and count sensitivity results informed the fixed fragment control. We used no result table or code from that study. The cohort is shared.

  2. usesHFO concentration in 1 s bins gave no clear SOZ rank gain over count on 1,285 channels in the first hour of 18 SEEG records sci:sha256:d3919c57fc8643409a319cb9f79cfb8f867b3bb607d3aaceb424d9c9506cfdd0

    Its one second HFO concentration test in the same cohort informed the new timing question. We added local count conditioning, interval joining, same-shaft pairs, contact position control, and fully refitted patient bootstrap fits. We used no result table or code from that study.

  3. usesThe STE spike selection AUC change interval included zero within shafts in the first hour of 17 SEEG records under independent, exchangeable patient sampling sci:sha256:04342d6a52677a89f1cc9003d6c76e3993e464bed70b006539e38bd1b33ab96a

    This publication supplied the verified SEEG event archive, metadata, EDF headers, parser, retrieval code, and source export snapshot. We adapted the parser to retain intervals. We checked the public source bytes again. Its spike-selection results were not calculation inputs.

  4. usesdoi:10.18112/openneuro.ds005398.v1.1.3

    Source event marks and metadata from OpenNeuro ds005398 version 1.1.3 were used; the saved dataset metadata states CC0.

  5. doi:10.1088/1741-2552%2Fac520f
  6. doi:10.1111/epi.18545