In 8 SEEG patients, CCEP N1 latency increased with distance, but path effects were not significant after distance control
We examined whether cortico-cortical evoked potential (CCEP) N1 latency contains path information beyond distance in single-pulse electrical stimulation data from OpenNeuro ds005448 v1.0.0. The analysis used expert-checked detections for 8 SEEG patients as the primary cohort and 5 ECoG patients as a secondary cohort (8,344 responses total). We wrote the analysis plan before calculating statistics. In the SEEG cohort, latency increased with distance in all 8 patients (mean ordinary least squares slope 0.61 ms/mm, range 0.18–1.37; Holm-adjusted p = 0.023; intercept 27.5 ms). Apparent speed was 1.6 m/s from the mean ordinary least squares slope and 2.9 m/s from the mean Theil–Sen slope; neither is a conduction velocity. With distances of at least 10 mm, the slope remained positive in 7/8 patients (Holm p = 0.047). A delay for recording contacts on another shaft was +4.5 ms (6/8 patients; Holm p = 0.094), and the distance-controlled forward–reverse latency correlation was 0.12 (6/8; Holm p = 0.094); neither was significant after Holm correction. These results do not provide evidence of path information beyond distance in this small, single-centre SEEG cohort. Results in all 13 patients were significant for all three tests (p ≤ 0.0034), but the shaft and forward–reverse effects were driven mostly by ECoG grids. Age showed no significant correlation with median latency. Limitations include 8 SEEG patients, Euclidean contact distance rather than tract length, reliance on the dataset authors’ peak detections, and low power for medium effects.
cortico-cortical evoked potentials · N1 latency · stereo-encephalography · single-pulse electrical stimulation · distance · intracranial EEG · OpenNeuro ds005448
References
2- usesIn six SEEG patients, SOZ contacts did not receive significantly more CCEP N1 responses after distance control sci:sha256:50d7449a6feefc0875ffd1fb06586e32df6d2856efee1a3b0302b99bd622f9bf
We use the archived ds005448 input files (N1 detections, electrodes, channels, participants), their SHA-256 hashes, and the same observation and exclusion rules.
- usesdoi:10.18112/openneuro.ds005448.v1.0.0
Uses the expert-checked N1 detections, electrode coordinates, channel status and participant ages from OpenNeuro ds005448 v1.0.0 (STReEF).
Cited by
6 publicationsPublic catalog entries on Sciscape.
- usesAfter de-duplication, CCEP N1 latency increased with distance in 17 archived SEEG patients
Origin of the ds005448 N1 response table (via 13e7a6db).
- usesCCEP N1 reciprocity was weaker and inconsistent across eight SEEG patients
Original extraction of the expert-checked N1 rows from ds005448.
- usesThree duplicate recordings reduce the pooled SEEG sample to 17 people, while the CCEP latency-distance slope remains positive
Archived ds005448 CCEP response table (via 13e7a6db).
- usesCounting each SEEG person once preserved the CCEP N1 latency-distance slope in 17 people from 2 institutions
Utrecht ds005448 expert-checked N1 responses (archived input of 13e7a6db).
- supportsCCEP N1 latency increased and N1 presence decreased with distance in Mayo SEEG data, with effect sizes dependent on detector threshold
SEEG-only latency-distance increase replicates in Mayo SEEG; the 0.61 ms/mm value is inside the 5 SD CI but above the 3.4 SD CI.
- supportsCCEP N1 latency rose with distance in 19 of 20 SEEG patients, but the estimated apparent speed depended on analysis choices
With harmonized rules and two more datasets, the positive latency-distance slope is found again (Utrecht 0.55 ms/mm, pooled 0.47 ms/mm).
- usesCCEP N1 latency rose with distance in 19 of 20 SEEG patients, but the estimated apparent speed depended on analysis choices
Utrecht ds005448 pair-level N1 table (results/responses.tsv) is an input.